UL Listed or R/C AWM wires that have an conductor gauge range of
AWG 22–14 shall be used.
-
The minimum conductor gauge for connection between the power sourcing
equipment (PSE) or power injector and the powered device (PD) is 26 AWG.
•
Connectors
-
This product is not intended for outside wiring as covered by Article 800 in the
National Electrical Code, NFPA 70.
-
Power Connector – For UL security applications, the product shall be powered
by a UL 294 Listed or UL 603 Listed Class 2 low-voltage power limited power
supply that is capable of 4 hours of standby power.
-
Network Connector – Power over Ethernet (PoE) shall be supplied by a UL 294
Listed Class 2 power limited injector that provides 44–57 V DC, 15.4 W and 4
hours of standby power. Compliance with IEEE 802.3 (at or af) specifications
has not been verified as part of UL 294/B.
-
Tampering Alarm Pin Header – To comply with UL 294/7.2.1 (Enclosure), the
tampering alarm shall be connected to a sound alarm.
•
System Considerations
-
The Axis product, whether it is a standalone door controller or a system of
door controllers, shall not impair the intended operation of the panic hardware
used in conjunction with it.
•
Wall and Ceiling Mount
-
If using a junction box to mount the Axis product, the junction box shall be
UL Listed.
•
Assign an IP Address
-
The functionality of AXIS Camera Management, see page 36, has not been
evaluated by UL.
•
Maintenance Instructions
-
For maintenance instructions (some steps require access to the product's
webpages), see page 40. For information about how to configure the Axis
product using the product's webpages (AXIS Entry Manager), see the User
Manual.
AXIS A1001 Network Door Controller