Wire Area
NO TICE
TICE
NO
NO
TICE
Each wire shall have an area that corresponds to an conductor gauge range of
AWG 28–16 (CSA) or AWG 22–14 (cUL/UL). Select cables in compliance with your local
regulations.
AWG
28–16
22–14
Connectors
For information about the connectors' positions, see Hardware Overview on page 13.
For connection diagrams and information about the hardware pin chart generated through the
hardware configuration, see Connection Diagrams on page 24 and Configure the Hardware on
page 27.
The following section describes the connectors' technical specifications.
Reader Data Connector
6-pin terminal block supporting RS485 and Wiegand protocols for
communication with the reader.
The RS485 ports support:
• Two-wire RS485 half duplex
• Four-wire RS485 full duplex
The Wiegand ports support:
• Two-wire Wiegand
Function
RS485
RS485
AXIS A1001 Network Door Controller
Diameter mm (in)
0.321–1.29 (0.0126–0.0508)
0.644–1.63 (0.0253–0.0641)
Pin
1
A-
2
B+
3
A-
4
B+
19
Area mm
0.0810–1.31
0.326–2.08
Notes
For full duplex RS485
For half duplex RS485
For full duplex RS485
For half duplex RS485