Door Connector
Two 4-pin terminal blocks for door monitoring devices (digital input).
All door input pins can be supervised. If the connection is interrupted, an
alarm is triggered. To use supervised inputs, install end of line resistors.
Use the connection diagram for supervised inputs. See page 26.
Function
Pin
1, 3
0 V DC (-)
Input
2, 4
Auxiliary Connector
4-pin configurable I/O terminal block for:
• Auxiliary power (DC output)
• Digital Input
• Digital Output
• 0 V DC (-)
For an example connection diagram, see Connection Diagrams on page
24.
Function
Pin
1
0 V DC (-)
2
DC output
AXIS A1001 Network Door Controller
Notes
For communicating with door monitor.
Digital input — Connect to
pin 1 or 3 respectively to activate,
or leave floating (unconnected) to
deactivate.
Note: This pin can only be used for
input.
Notes
For powering auxiliary equipment.
Note: This pin can only be used as
power out.
21
Specifications
0 V DC
0 to max 40 V DC
Specifications
0 V DC
3.3 V DC
Max load = 100 mA