Learning In Manual Mode; Learning In Combined Mode; Checking Movement Of Gate Leafs; Testing And Commissioning - Nice Moon MC824HR Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
– If the first two manoeuvres (a and b) are not "closing" but are "opening",
press key " " or " " to stop the learning phase. At this point, on the gear-
motor that completed the opening manoeuvre, invert the polarity of the two
wires of gearmotor M1 (terminals 7 and 9) and of M2 (terminals 10 and 12)
and then start the procedure from point 01;
04. At the end of the Closing manoeuvre of the 2 motors (d), leds "L3" and
"L4" turn off to indicate the that the procedure has been completed cor-
rectly.
– During the automatic learning procedure, if a photocell trips or a device con-
nected to the "stop" input is activated, the procedure is interrupted and led
L1 starts flashing. To resume the learning process, the procedure must be
started again from point 01;
– The automatic learning procedure can be repeated at any time, also after
installation; for example following modifications to the position of the
mechanical stops.

3.7.2 - Learning in manual mode

Caution! – From step 03 onwards:
– to move from led L1 to L8, briefly press key
cate the current position);
– to move the motor in one or the other direction, press and hold key
01. Press and hold keys "Set" and " " at the same time.
02. Release the keys when led "L1" starts flashing (after approx. 1 second);
Note – After 3 seconds have elapsed, if the keys "Set" and " " are not
released, the "automatic learning" procedure is started up, and not the
manual procedure.
03. • LED L1 flashes: position 0 of M1
To bring motor 1 to position 0 (fig. B): press and hold down the
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L1 remains on and
on releasing the "Set" key LED L2 begins flashing).
• LED L2 flashes: position 0 of M2
To bring motor 2 to position 0 (fig. B): press and hold down the
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L2 remains on and
on releasing the "Set" key LED L3 begins flashing).
• LED L3 flashes: position SA of M2
To bring motor 2 to position SA (fig. B): press and hold down the
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L3 remains on and
on releasing the "Set" key LED L4 begins flashing).
• LED L4 flashes: position A of M1
To bring motor 1 to position A (fig. B): press and hold down the
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L4 remains on and
on releasing the "Set" key LED L5 begins flashing).
• LED L5 flashes: position A of M2
To bring motor 2 to position A (fig. C): press and hold down the
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L5 remains on and
on releasing the "Set" key LED L6 begins flashing).
• LED L6 flashes: position SC of M1
To bring motor 1 to position SA (fig. C): press and hold down the
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L6 remains on and
on releasing the "Set" key LED L7 begins flashing).
• LED L7 flashes: position 1 of M1
To bring motor 1 to position 1 (fig. C): press and hold down the
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L7 remains on and
on releasing the "Set" key LED L8 begins flashing).
• LED L8 flashes: position 1 of M2
To bring motor 2 to position 1 (fig. C): press and hold down the
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it to exit programming (after 2 seconds LED
L8 remains on until the "Set" key is released).
Note – Manually programming a system with one gearmotor: proceed as
described at the beginning of this paragraph from step 01 to step 03, proceed
as follows:
- program the positions relating to LEDs L1 (0 of M1) and L7 (1 of M1)
as follows: keep the "Set" key pressed for at least 3 sec. and then release it
(after 2 sec. the LED stays on and, upon releasing the "Set" key, the next LED
starts flashing).
- do not program the positions relating to LEDs L3 (SA of M2) - L4 (A of
M1) - L6 (SC of M1)
- to move between positions, briefly press the
4 – English
Warnings:
or
(the led flashes to indi-
or
key.

3.7.3 - Learning in combined mode

Perform this procedure after completing the automatic learning cycle:
01. Press and hold keys "Set" and " " at the same time.
02. Release the keys when led "L1" starts flashing (after approx. 1 second);
Note – After 3 seconds have elapsed, if the keys "Set" and " " are not
released, the "automatic learning" procedure is started up, and not the
manual procedure.
03. Briefly press key " " or " " to move the flashing led (L1-L8) to the position
to be programmed and proceed for each position, as described in step 03
of the manual learning procedure (paragraph 3.7.2).
Repeat this operation for all other positions to be modified.
To complete the manual learning process, press key " " repeatedly to move
the led that flashing beyond position L8.

3.8 - Checking movement of gate leafs

At the end of the learning procedure, it is advisable to make the control unit
perform a few opening and closing manoeuvres to ensure that the gate moves
correctly and to check for installation or setting defects.
01. Press "Open". Verify correct offset of the leafs on opening and ensure that
the opening manoeuvre comprises the acceleration phase, the constant
speed phase and the deceleration phase. At the end of the manoeuvre,
the leafs must stop a few centimetres from the opening mechanical stop.
or
.
02. Press the "Close" key and check that the closure manoeuvre includes the
acceleration, constant speed and deceleration phases. Check that the leaf
closure offset is correct. At the end of the manoeuvre, the leafs must be
perfectly closed on the mechanical closure stop.
03. Make sure that the flashing light flashes at intervals of 0.5 sec on, 0.5 sec
off during manoeuvres.
or
4

TESTING AND COMMISSIONING

These are the most important phases of automation set-up for ensuring maxi-
or
mum system safety. The test can also be performed as a periodic check of
automation devices. Testing and commissioning of the automation must be
performed by skilled and qualified personnel, who are responsible for the tests
required to verify the solutions adopted according to the risks present, and for
ensuring observance of all legal provisions, standards and regulations, and in
particular all requirements of the standard EN 12445, which establishes the test
or
methods for checking automations for doors and gates. The additional devi-
ces must undergo a specific test for functionality and correct interaction with
MC824HR. Refer to the instruction manuals of the individual devices.

4.1 - Testing

The sequence of operations to be performed for testing and described below
or
refers to a typical system (fig. 2):
1 Ensure that everything stated in the "Installation warnings" chapter has
been observed.
2 Release the gearmotors for manual operation as described in the relevant
instruction manual. Pushing at the prescribed point for manual operation,
check that it is possible to open and close the leafs with a force lower than
or
390 N.
3 Lock the gearmotors (see relevant instruction manual).
4 Using the control devices (transmitter, key-operated selector switch or con-
trol pushbuttons, etc.), perform tests of opening, closing and stopping the
gate, and ensure that leaf movement corresponds to specifications. Test
several times to check for leaf movement and any defects in assembly or
adjustment and any possible points of friction.
or
5 Check operation of all system safety devices one at a time (photocells, sen-
sitive edges, etc.). Each time a device is activated the "BLUEBUS" LED on
the control unit must flash rapidly twice to confirm acknowledgement of the
event.
6 If hazardous situations generated by the moving leafs are protected by
means of impact force limitation, measure the force as specified in the stan-
or
dard EN 12445. If gearmotor force control is used as auxiliary function with
the system for reduction of impact force, test and identify the setting that
obtains the best results.

4.2 - Commissioning

Commissioning can only be performed after positive results of all test
or
phases.
1 Prepare the automation technical documentation, which must contain the
following documents: overall drawing of the automation, electrical wiring
diagram, risk assessment and solutions adopted, manufacturer's declara-
tion of conformity for all devices used and installer's declaration of confor-
mity.
2 Apporre sul cancello una targhetta contenente almeno i seguenti dati: tipo
di automazione, nome e indirizzo del costruttore (responsabile della "messa
in servizio"), numero di matricola, anno di costruzione e marchio "CE".
3 Affix a dataplate on the door, specifying at least the following data: type of
automation, name and address of manufacturer (responsible for commissio-
ning), serial number, year of construction and CE mark.
4 Compile the "Operation manual" for the automation and forward it to the
owner.
5 Compile the form "Maintenance schedule" containing all maintenance
instructions for all devices in the automation and forward it to the owner.