Elixo 500 3S io
4.5. Locking the motorisation
1) Turn the release handle to the le .
2) Move the gate manually until the drive mechanism re-locks.
[1]
[2]
3) Turn the key a quarter of a turn to the right.
4) Remove the key.
Attention
The motorisation must be locked before a new command.
5. MAINTENANCE
5.1. Checks
5.1.1. Safety devices (cells)
Check for correct operation every 6 months.
5.1.2. Backup battery
For optimum battery life, it is recommended that the main power supply be
switched off and the motor operated using the battery for several cycles,
three times a year.
5.2. Replacing the battery
5.2.1. Keygo io
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
or
6. TECHNICAL DATA
Power supply
Max. power consumption
Climatic operating conditions
Radio frequency
Number of memorisable channels:
1 W controls
(Keygo io, Situo io, etc.)
Remote lighting output
EN
230 V - 50/60 Hz
600 W (with 500 W remote
lighting)
- 20°C/+ 60°C - IP 44
868 - 870 MHz
< 25 mW
Complete/pedestrian opening
control: 30
Lighting control: 4
Auxiliary output control: 4
230 V - 500 W
Halogen or incandescent only
5