Turn two stainless steel screws into the anchors and
3.
EN
leave 2.5 mm of the screw out (pic 3)
Put the appliance to the wall, pull down until it
4.
secured. (pic 4)
After securing it firmly to the bottom two screws,
5.
screw the last three screws as picture
6
Usage and Storage Instructions
OPERATION
Push the ON/OFF (0/I) button located at the back of
the appliance to connect power supply. There is a "D"
sound and screen will display in full for 3 seconds, then
appliance enters into standby mode. Push ON/OFF (0/I)
button again to disconnect power supply.
On/standby switch
Power setting
Window
open detection
2.5
Timer
3
Icon
d1, d2, d3, d4,
d5, d6, d7
P1,P2,P3,P4,P5 Factory pre-set program
UP
Press
, once to switch on the appliance. Press
to switch it off.
Set Current Day and Time:
1.
4
When appliance is ON, long press
activate current day setting.
Screen will display d1 and it flashes, then press
1).
to set Day of the week among d1, d2, d3, d4, d5,
d6, d7 in cycle. Press
day setting.
Then appliance enter into time setting. Hour icon
2).
flashes, press
00-23 in cycle. Press
Then follow the same way to set minutes. Finally
3).
press
After setting finish, press
to check if the current day and time setting is correct.
Screen will automatically show Day, Hour, Minutes
in turns within1 second each, then switch back to
5
temperature display.
For exampe, you have set today is Wed. 12:45 a.m.,
screen will show d3, 12: 45 accordingly.
Note: At the first usage, icon
current day and time are set. Please finish the setting
before any other usage.
Prog
Mode
LED display
Meaning
working at Full power 2000W
Working at 1000W
Anti-frost function
Window open detection function
Timer function to switch off
Mon. Tue. Wed. Thur. Fri. Sat. Sun.
Self-program setting
for 3 seconds to
once to confirm the current
or
to set current hour among
once to confirm hour.
once to confirm setting.
once in standby mode
will keep flashing until
Program
setting
Mode switch:
Р1, Р2, Р3,
Р4, Р5, UP
Plus button
for timer/
temperature
Minus button
for timer/
temperature
again
or