V2 City4 Manual De Instrucciones página 30

Cuadro de maniobras digital universal para un motor 230v/120v
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Partial opening time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will
open the gate only, for a shorter time. Max allowed time to be setup is
t.AP.
Closing time
The motor will be operated for the setup time in the closing phase;
In case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
To avoid that the gate does not close completely, we recommend to
setup a longer time than t.AP opening time.
Partial closing time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will use
this time to close the gate. Max allowed time to be setup is t.CH1.
To avoid that the door does not close completely, we recommend to
setup a longer time than t.APP opening time.
Lock time
Before the opening phase begins, the control unit will energize the
electric lock in order to release it and enable the gate motion.
t.SEr time will fix the energizing time.
WARNING: in case the gate has no electric lock, set the value
0 ('no' will appear on display).
Lock advance time
While the electric lock is energized, the gate will stay standstill for
t.ASE time, to make its release easier.
In case t.ASE is lower than t.SEr, the lock energizing will go on while
the gate will start moving.
WARNING: in case the gate has no electric lock, set the value 0.
28
Tabla de contenido
loading

Este manual también es adecuado para:

City4

Tabla de contenido