IndraDynA_ATEX
Purging Connections
DOK-MOTOR*-IDYN*A*ATEX-IB02-D5-P
Motor MAF ...
100 ... 130
160 ... 180
Fig. 5-11:
Coolant connection threads
Note:
When making the connections, ensure that the coolant
connections are sufficiently tight and then check their
impermeability.
The connection of an ATEX motor with an EEx p control device has to be
done with a pipe or a tube with a maximum internal diameter of 8 mm.
If plastic pipes are used, the maximum outer diameter is 13 mm.
Possible electrostatic discharge from plastic
pipes!
⇒ Use only plastic pipes that are certified for use in
explosion-protected areas.
CAUTION
Connect the pneumatic purging gas lines by heeding the maximum
permitted bending cycles according to Fig. 5-12.
p:
Maximum permitted input pressure on EEx p control device = 3 bar
Fig. 5-12:
Purging gas connection layout
Note:
Should more than one motor be operated with a control
device, apply them in a row when connecting the purging gas
tube (see Fig. 5-12)!
Operating Instructions
Coolant connection thread
G1/4"
G1/2"
Anschlussschema.tif
5-13