Programming From The Control Panel - INIM Electronics Air2 Manual De Instalación Y Programación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Press the "ENROLL" button on the device you wish to enroll. Press simultaneously
buttons F3 and F4 on the remote-control key. Within 4 seconds, LED DL2 should
flash to indicate correct reception of the device and its enrollment.
Unenroll: LED DL3 will emit in series 2 blinks followed by a pause. LEDs DL1, DL4
and PRG will remain off.
Press the "ENROLL" button on the device you wish to unenroll (delete). Press
simultaneously buttons F3 and F4 on the remote-control key. Within 4 seconds,
LED DL2 should flash to indicate that the device has been received and
unenrolled.
Change transmission/reception channel: LED DL3 will emit in series 3 blinks
followed by a pause.
LED DL4 emits a number of blinks equal to the number of the current channel. 3
channels are available. Press button P2 to activate the successive channel to the
one currently operating on the Air2-BS200 module. At this point, press the
"ENROLL" button on all the detectors and sounders, access the "ENROLL" menu on
the Aria keypad and press buttons F3 and F4 simultaneously on all the remote-
control keys. This will synchronize the system wireless devices with the new
channel.
Enable/Disable tamper Air2-BS200: LED DL3 will emit in series 4 blinks
followed by a pause.
LED DL4 indicates the status of this option: OFF = Tamper enabled; ON = Tamper
disabled. Press button P2 to toggle the status of this option. If the Tamper option
is disabled, the status of both microswitches will be ignored.
Enable/Disable rolling-code authentication on Air2-KF100: LED DL3 will
emit in series 5 blinks followed by a pause.
LED DL4 indicates the status of this option: OFF = Rolling code authentication
enabled; ON = Rolling code authentication disabled. Press button P2 to toggle the
status of this option.
Addressing: LED PRG will go On solid. LED DL1-4 indicates the current address.
This phase is available on all control panel models. Refer to paragraph 4-6
Addressing the Air2-BS200.
To restore the factory default settings, press and hold the P2 button until the 4
LEDs (DL) come ON during Phase 2 - Unenroll, as previously described.
The actual programming process for Inim control panels offers the following
parameters for the management of the Air2 wireless system:
Table 24: Control panel parameters
Parameter
Instant reset of
wireless magnetic
contact
Wireless supervision
time
Wireless data reset
22
Programming from the
If this option is enabled, reset of the magnetic reed sensor of
wireless detectors will be signalled instantly (otherwise signalling
has a maximum delay of 10 seconds).
This parameter allows the selection of the supervision time of
wireless devices. On expiration of the programmed time, any
wireless devices which do not respond will be signalled as lost.
Accepted values: 12 to 250 minutes.
After selecting this option, pressing the OK will delete all the data
relating to the Air2-BS200 device.
The data relating to the wireless detectors and remote-control
key will not be contextually deleted, nor will the devices simulated
by the Air2-BS200 transceiver be deleted from the configuration.
Control panel
Function
Wireless accessories
PHASE 2
PHASE 3
PHASE 4
PHASE 5
PHASE 6
FACTORY DATA
5-4
Programming
Tabla de contenido
loading

Productos relacionados para INIM Electronics Air2

Tabla de contenido