INIM Electronics Air2 Manual De Instalación Y Programación página 19

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation and programming manual
Device
Terminal type
All devices
IR100
Infrared
FD100
Smoke detector
Passive infrared
XIR200W
detector
OTT100W
ODI100W
Outdoor terminal
UT100
Programming
Table 22: Wireless terminal parameters
In order to increase battery life, the PIR detector will deactivate when the partitions it
belongs to are disarmed and will only activate when the partitions it belongs to arm.
Deactivated detectors do not generate alarms. When the partitions arm, there may be a
delay of up to 3 minutes before the detector receives the activation command.
The red LED on the device provides visual signalling of alarm or tamper conditions on the
This option will be enabled on all the terminals of the Air2 device.
If this option is disabled, open/dislodgement tamper on Air2 detectors will not generate
/
This is the number of pulses (each as long as the programmed "Alarm pulse Duration")
necessary to generate a zone alarm event. If this value is more than 1, you must also
This parameter applies only when the "Alarm pulse num." is higher than 1.
This is the window during which a number of alarm pulses must be detected (each lasting
as long as the programmed "Al.pulse Duration"). The number of alarm pulses must equal
or exceed the value programmed for "Alarm pulses", before the system generates an
alarm. This time window can be expressed in seconds or minutes.
This is the length of time (after detection of alarm conditions) the zone will allow before
generating an alarm. Expressed in multiples of 15 milliseconds or minutes.
from 1 (least sensitive) to 4 (most
1=0.08 dB/m; 2=0.10 dB/m; 3=0.12 dB/m
; 4=0.15 dB/m (default)
from 1 (least sensitive) to 15 (most
10 is the default value
from 1 (least sensitive) to 10 (most
5 is the default value
from 1 (least sensitive) to 15 (most
10 is the default value
from 1 (least sensitive) to 10 (most
5 is the default value
Parameter
SmartLiving
Disable detector when partition is disarmed
Use detector LED
device itself.
Bypass tamper
the respective events.
Alarm pulses
program the "Multi-pulse time" parameter.
Multi-pulse time
Alarm pulse Duration
Detector sensitivity
sensitive)
Detector sensitivity
Infrared detector sensitivity
sensitive)
Tamper detector sensitivity
sensitive)
Infrared detector sensitivity
sensitive)
Tamper detector sensitivity
sensitive)
Prime
from 1 (least sensitive) to 10 (most
sensitive)
from 1 (=0,08 dB/m) to 10 (=0.15 dB/m
default)
from 1 (least sensitive) to 10 (most
sensitive)
6 is the default value
from 1 (least sensitive) to 10 (most
sensitive)
3 is the default value
from 1 (least sensitive) to 10 (most
sensitive)
6 is the default value
from 1 (least sensitive) to 10 (most
sensitive)
3 is the default value
19
Tabla de contenido
loading

Productos relacionados para INIM Electronics Air2

Tabla de contenido