In order to configure the Air2-BS200 in the control panel it is necessary to assign
an address between 1 and 30 (to set the address follow the instructions in
paragraph 4-6 Addressing the Air2-BS200).
The selected address will be assigned to the simulated reader (which processes
and manages wireless transmissions in the same way as keys) and to the first 10
expansion boards, also simulated, with successive addresses "ADD", "ADD"+1, ...,
"ADD"+9.
Conditions for secure deployment and operations:
there must be no other transceivers at the selected address
the simulated reader must be enrolled on the control panel
there must be no other readers at the same address (nBy/X or built into the
keypad)
the simulated reader need not be associated with any partitions
the simulated expansion boards must be enrolled on the control panel
an expansion board will be considered part of the wireless network only when one
of its terminals is configured as "wireless"
a simulated expansion board cannot share its assigned address with other
hardwired FLEX5 expansion boards.
A terminal can be considered a "Wireless" terminal only under the following
conditions:
it must not be configured as a "Double" zone (D)
if configured as a "Zone", it must not be configured as "Shock" in the detector type
field
it must be assigned to an expansion board (and not to the control panel or
keypads)
The Inim intrusion control panel can manage up to 4 Aria keypads and 4 Hedera
sounders for each Air2-BS200 installed. However, each control panel model
supports a maximum number of keypads and sounders which must be respected.
During the addressing phase it is necessary to use free addresses only and to
ensure that no other keypads (Aria/HG, Joy, Concept, NCode or Alien) are present
at the address of the Aria/W keypads, or other sounders (Ivy-B) at the address of
the Hedera sounderflashers to be included in the configuration.
For the addressing procedure and the programming of these devices, refer to the
respective manuals.
12
OPERATING PRINCIPLES

Air2-BS200 address

Wireless terminals

Aria Keypads and
Hedera sounders
Wireless accessories
Chapter 3
3-1
3-2
3-3
Operating principles