LCD (Liquid-crystal
display)
MAX MIN
REL
0
10
20
Alternating current
AC
Direct current
DC
Diode test
Continuity buzzer
Auto range mode
AUT O
MAX
The mimum value is being measured.
The minimum value is being measured.
MIN
DCA zero and relative measure
REL
Aotu power of f
Battery low
This indicates that the display data is
H
being held.
Percent (Duty cycle)
%
m V, V
Milli-volts, Volts (Voltage)
A
Amperes (Current)
n F, F
Nanofarad, Microfarad
Ohms, Kilo-ohms, Mega-ohms
, k
,
(Resistance)
M
Hertz, Kilo-hertz (Frequency), Milohertz
H z , k H z
www.grupotemper.com
Specifications
Calibration is required once a year,
to be carried out at a temperature
between 18°C and 28°C (64F° to
%
82F°) and relative humidity below
n F
75%.
mVA
Mk
Hz
General Specifications
30
40
•
•
•
•
•
•
•
•
•
•
•
•
•
KP 2102
Digital clamp meter
Auto range. Over range
protection is provided for all
ranges.
Maximum voltage between
terminals and earth ground:
1000V DC or 750 rms AC
Operating altitude: max. 2000
meters (7000 ft.)
Display: 4000 counts with analog
bar LCD display
Maximum value display: 4000
digits
Polarity indication: automatic; '-'
for negative polarity.
Over range indication: '0L' or
'-0L'
Converter Rate: 3 times/sec; Bar
graph: 30 times/sec.
Unit indication: function and
unit.
Auto power off time: 15 minute.
Operating power : 1.5V×3 AAA
batteries
Battery low indication: '
LCD
Temperature factor:
<0.1×Accuracy /°C
Instructions manual |
' on
29