technicians authorized by the manufacturer, in compliance
with current safety standards and the instructions in this
manual.
•
Identify the specific appliance model. The model number is
detailed on the packing and on the appliance data plate.
•
The appliance must be installed in a well-ventilated room.
•
Do not obstruct any air vents or drains present on the
appliance.
•
Do not tamper with appliance components.
4 REFERENCE STANDARDS AND LAWS
Install the appliance in compliance with no. 74 of 12 April
1996.
Install the appliance in compliance with the prescriptions of
EN1717 and the water pollution regulations in force in your
country.
5 UNPACKING
•
Check the state of the packing and in the event of damage,
ask the delivery person to inspect the goods.
•
Remove the packing.
•
Remove the protective film from the outer panels.
•
Use a suitable solvent to remove any residual adhesive
from the panels.
6 POSITIONING
•
The overall dimensions of the appliance and the position of
connections are given on the installation diagram at the
start of this manual.
•
The appliance can be installed singly or in combination with
other appliances in the same product range.
•
The appliance is not suitable for integrated installation.
•
Position the appliance at least 10 cm from adjacent walls.
This distance can be reduced in the presence of non-
combustible walls or heat-insulated walls.
•
Level the appliance by means of the height-adjustable feet.
6.1 APPLIANCE ASSEMBLY WITH BASE, BRIDGE, AND
CANTILEVER SOLUTIONS
Follow the instructions provided with the type of support
utilized.
6.2 FIXING THE APPLIANCE TO THE FLOOR
Appliances of 40cms in width installed alone must be fixed to
the floor. Use the flanged feet provided.
6.3 JOINING APPLIANCES TOGETHER IN LINE
• Pull out the control knobs , remove control panel.
• Place the appliances side by side and adjust the tops to the
same height.
• Unite the appliances using the screws.
7 EXHAUSTING FUMES
The appliance should be installed in a well-ventilated area, if
possible under a vent hood, in compliance with all applicable
regulations in force. This will ensure that all burnt gases
produced during the combustion process are completely
exhausted. The amount of air required for combustion is
shown in the "Technical Specifications Table" at the end of
this manual, under "Air required for combustion".
In compliance with applicable installation regulations in force,
our appliances belong to the type shown under "Construction
type" in the "Technical specifications table".
30
7.1 APPLIANCE TYPE "A1"
Position the "A1" type appliance below an extractor hood to
ensure smoke and fumes generated by cooking are
removed.
7.2 APPLIANCE TYPE "B21"
Position the "B21" type appliance below an extractor hood.
7.3 APPLIANCE TYPE "B11"
Fit the "B11" type appliance with a suitable flue, available
from the appliance manufacturer. Follow the assembly
instructions provided with the flue.
Connect the flue to a 150/155 mm diameter hose, heat
resistant to 300°C.
Vent to the outside or into an efficient flue. The hose length
must not exceed 3 metres.
8 CONNECTIONS
The position and dimensions of connections are given in the
installation diagram at the start of this manual.
8.1 CONNECTION TO THE GAS SUPPLY
•
Check that the appliance is designed to operate with the
type of gas supply present on site.
•
Check the information given on the decals on the packing
and appliance.
•
Convert the appliance to the local gas type, if necessary.
Follow the instructions at the next paragraph "Conversion
to a different type of gas".
On top appliances a rear connection is also available.
Remove the plug present and screw it tightly onto the front
connector.
•
A rapid-action gas shut-off valve must be fitted upstream of
the appliance in an easily accessible position.
•
Do not use connection pipes having a diameter smaller
than that of the appliance's gas connector.
•
Once the appliance has been installed, check for gas leaks
at the connection points.
8.2 ELECTRICAL CONNECTIONS
Check that the appliance is designed to operate at the
voltage and frequency of the power supply present on site.
Check the details given on the appliance data plate.
•
At an easily accessible point up line of the appliance, fit an
all-pole disconnect switch of suitable capacity with a
contact breaking distance of at least 3 mm, and a highly
sensitive differential protection device. The maximum
permitted leakage current is 1 mA/kW.
•
A flexible rubber cable with insulation specifications not
lower than type H05 RN-F must be used for connection.
•
Connect the power supply cable to the terminal board as
shown in the wiring diagram supplied with the appliance.
•
Secure the power supply cable with the cable clamp.
•
Protect the power supply cable on the outside of the
appliance with a rigid plastic or metal pipe.
8.3 PROTECTIVE
EARTH
CONNECTIONS
Connect the appliance to an efficient ground circuit. Connect
the earth conductor to the terminal with the symbol
the main terminal board.
Connect the metal structure of the appliance to the
equipotential node.
AND
EARTH
BONDING
next to