INSTALLATION INSTRUCTIONS
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
1. PROVIDE ADEQUATE GAS SUPPLY
Your range is designed to operate at a pressure of
5" of water column on natural gas or 10" of water
column on LP.
Make sure you are supplying your range with the type of
gas for which it is configured.
This range is convertible for use on natural or LP gas.
When using this range on LP gas, conversion must be
made by a qualified LP installer before attempting to
operate the range.
For proper operation, the pressure of natural gas supplied
to the regulator must be between 5" and 13" of water
column.
8
30"
30"
9
"
1 / 16
"
11
3 / 32
2"
8
19 / 32
3"
14
"
5 / 16
2
"
3 / 8
For LP gas, the pressure supplied to the regulator must be
between 10" and 13" of water column. When checking for
correct operation of the regulator, the inlet pressure must
be at least 1" more than the operating (manifold) pressure
as given above.
The pressure regulator located at the inlet of the range
must remain in the supply line regardless of which type of
gas is being used.
A flexible metal appliance connector used to connect the
range to the gas supply line should have an I.D. of 5/8"
and a max of 5ft. In Canada, flexible connectors must be
single wall metal connectors less than 6 feet in length.
Recommended area for 120V outlet
on rear wall and area for through-
"
the wall connection of pipe stub and
shut-off valve.
Recommended area for through-
the floor connection of pipe stub
and shut-off valve.