Installation
(Con't)
two-stage compressors or 150 psi for sin-
gle stage compressors ASME safety valve
setting. Incorrect selection and installa-
tion of any tube, pipe or hose could result
in bursting and injury. Connect piping sys-
tem to tank using the same size fitting as
the discharge port.
INSTALLING A SHUT-OFF VALVE
A shut-off valve should be installed on
the discharge port of the tank to control
the air flow out of the tank. The valve
should be located between the tank and
the piping system.
Never install a
shut-off valve
between the compressor pump and the
tank. Personal injury and/or equipment
damage may occur. Never use reducers
in discharge piping.
When creating a permanently installed
system to distribute compressed air, find
the total length of the system and select
pipe size from the chart. Bury under-
ground lines below the frost line and
avoid pockets where condensation can
gather and freeze.
Pump
Pressure
Gauge
Safety
Valve
Tank
Drain Cock
Figure 1 - Vertical Unit Identification
Apply air pressure to the piping installa-
tion and make sure all joints are free
from leaks BEFORE underground lines
are covered. Before putting the compres-
sor into service, find and repair all leaks
in the piping, fittings and connections.
MINIMUM PIPE SIZE
FOR COMPRESSED AIR LINE
Length Of Piping System
CFM
25'
50'
20
3/4"
3/4"
40
3/4
1
60
3/4
1
100
1
1
WIRING
All wiring and
electrical connec-
tions must be performed by a qualified
electrician. Installations must be in
accordance with local and national
codes.
Overheating, short
circuiting and fire
damage will result from inadequate
wiring.
Discharge Tube
Pump
Motor
Pressure
Switch
Pressure
Gauge
Factory Mounted
Magnetic Starter
(if applicable)
Tank Shut off
Valve
(available
separately)
Discharge Port
Tank
Drain Cock
Isolation Pads
(available separately)
3
Premium and Professional Series
Wiring must be installed in accordance
with National Electrical Code and local
codes and standards that have been set
up covering electrical apparatus and
wiring. These should be consulted and
local ordinances observed. Be certain that
adequate wire sizes are used, and that:
1. Service is of adequate ampere rating.
2. The supply line has the same electri-
cal characteristics (voltage, cycles and
100'
250'
phase) as the motor.
3/4"
1"
3. The line wire is the proper size and
that no other equipment is operated
1
1
from the same line. The chart gives
1
1
minimum recommended wire sizes for
compressor installations.
1
1
/
1
4
Recommended wire sizes may be larger
than the minimum set up by local ordi-
nances. If so, the larger size wire should
HP
5.0
Safety
Valve
MINIMUM WIRE SIZE
USE 75°C COPPER WIRE
Single
Three Phase
Phase
230V
208/230V 460/575V
8 AWG
12 AWG
14 AWG
Discharge Tube
Motor
Pressure Switch
Tank Shut off Valve
(available separately)
Discharge Port
Isolation Pads
(available separately)