Precautions And Warnings "During The Utilization" Of The Equipment - GNATUS ENDUS DUO Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PRECAUTIONS, RESTRICTIONS AND WARNINGS

Precautions and warnings "during the utilization" of the equipment

- The equipment should only be operated by duly enabled and trained technicians (Dental
Surgeons, Capacitated Professionals).
- If any maintenance should be required, only use services of the Gnatus Authorized
Technical Assistance.
- The equipment has been manufactured to handle both continuous.
- Although this equipment has been planned in accordance with the standards of
electromagnetic compatibility, it can, in very extreme conditions, cause interference with
other equipment. Do not use this equipment together with other devices very sensitive to
interference or with devices which create high electromagnetic disturbance.
- When the file accidentally touches the internal part of the canal of the dental root, the
length meter of canal advancement will become a bit abnormal, but, after a few seconds,
it will automatically go back to normal.
- Do not use damaged file supports; a precise measurement cannot be made with a
damaged file-holder.
- Never use the equipment if the power indicator of the batteries is blinking. It'll not
work properly if the batteries are worn out.
- Only use files and file support with plastic cables. If the file has a metallic cable, there
will be a current leakage when the fingers touch the cable, which will impede a precise
measurement of the root canal. Even if the file cable is made of plastic, check to not touch
the metallic part with the fingers.
- After coupling the counter-angle to the micromotor, pull it lightly to confirm that it is
correctly fastened.
- If the automatic reverse by torque frequently goes off, raise the torque configuration
in one line.
- If the micromotor overheats, remove the handpiece from the patient's mouth, wait
for it to cool down to reinitiate the treatment. The micromotor will begin to function again
when it's cool enough.
- Never apply excessive force to insert or advance the file on the canal.
- Use the reverse spinning mode carefully. Since this mode was designed to free the
fastened files, its spinning is fast and powerful, being able to break the file easily.
- Be careful when using the pedal, because stepping onto it will cause the micromotor
to function, even if the equipment is not measuring the root canal (the labial clip is not in
the patient's mouth or the file support is not in position).
The equipment is not indicated for patients and dentist-surgeons bearers
of a cardiac pacemaker.
Gnatus shall not be responsible for:
- Use of the equipment differing from that for which it is intended.
- Damages caused to the equipment, the professional and/or the patient by the incorrect
installation and erroneous procedures of maintenance, differing from those described in
these Instructions for use which come with the equipment or by the incorrect operation of it.
62
Tabla de contenido
loading

Tabla de contenido