Esquemas Eléctricos - Nordson LP90 Manual De Producto Del Cliente

Sistema de aplicación de fluidos
Tabla de contenido
48
Sistema de aplicación de fluidos LP90
Esquemas eléctricos
DISCONNECT
CUSTOMER SUPPLIED
U
208-240 VAC
1
SINGLE PHASE
50/60 HZ
V
3
5
PE
-PE
-DO O R
-1A21
DA NF OSS
132F0002
PE
PE
10
15   16
24   25
YEL
ORG
GRN
BL K  RED  BRN
-1W11
+MTR
+MTR
-1S11
-1M21
MOTOR
230V
PTC
1/4 HP
Figura 18
Esquema eléctrico (1 de 3)
MAIN
-1Q21
-1Z21
1
LINE IN
OUT LOAD
2
2
LINE IN
OUT LOAD
4
PE
6
35
35
to 2- 1
17
18
19
20
CUSTOMER
REMOTE
KEY - T O- L I NE
SUPPLIED
START/STOP
0-10 VDC
3
4
~ to 1-7
~ to 1-8
-1F31
BUSSM A NN
JJN-10
-XL1
33
3
10A
1
2
34
4
10A
1
2
-1F32
L1
-1M31
N
FAN
PE
200-240VAC/2.2A
0.5 H.P.
21
22
23
DRIVE ALARM
+-
N.O. CONTACT
G
31
-1K81
12
1-8
TANK FULL
REL A Y
4
8
JUMPER-BAR
JUMPER-BAR
-XL2
-1K81
9
1-8
TANK FULL
RELAY
1
5
29
26
27
30
NOTE: ALL CONNECTIONS TO -X3 MUST BE RUN INTO
PANEL THROUGH RIGID OR FLEXIBLE, CONDUCTIVE
CONDUIT.
-1H51
TANK LEVEL
FULL
W
3
to 2- 1
4
to 2- 1
CONTD>
+TANK
-1S51
TANK LEVEL
LOW
Tabla de contenido
loading

Tabla de contenido