Maintenance and Fault Repair
7.2
GreenVac mode
Note!
Damage to the pump is possible!
Make sure that no products, particularly liquid products (e.g.
sauces) get into the suction hose. These products can destroy the
pump.
Connect the plug-in connector on the hose of the GreenVac fitting to the snap-
on connector on the machine.
Connect the GreenVac fitting to the valve on the GreenVac container.
Switch the master switch to setting 2.
Chamber mode is thereby disabled and the evacuation procedure for the
GreenVac container commences.
You can follow the vacuum reading on the manometer on the GreenVac fitting.
When the vacuum reading display has reached the green area, you can undo
the connection between the fitting and the container. To do this tip the fitting on
its side and pull it away from the container.
To end GreenVac mode switch the master switch to 1 (transition to chamber
mode) or to 0 (machine switched off).
Undo the connection between the GreenVac fitting and the machine: Press the
washer backwards on to the snap-on connector.
Operating Instructions- Translation
8
Maintenance and Fault Repair
Danger!
Electric shock possible!
Pull out the mains power plug before starting work!
Spray water and steam jets in the operating site is prohibited!
Do not insert any objects into the ventilation slots of the machine.
Danger!
Under no circumstances should you undo the pneumatic spring.
Pneumatic springs have an extremely high internal pressure (up to
approx. 300 bar).
Prior to disposal the pneumatic spring must not be under pressure.
Please request our disposal instructions!
Danger!
Immediately replace Plexiglas cover with any cracks, hairline
cracks, deep scratches or any other damage.
To clean the cover, only use a suitable cleaning agent for Plexiglas.
Caution!
Combustion hazard!
Sealing pads and silicone rubber become hot during operation.
Wear protective gloves when carrying out maintenance work!
Caution!
Risk of injury!
Wear protective gloves when carrying out maintenance work!
19 04 249 - 01.01.2012