D. Prior to installation
Compare the data on the rating
plate with the data of the region-
al mains voltage before installa-
tion.
The appliance should only be
plugged into earthed sockets.
Maintain sufficient distance from
steam blasting equipment.
E. Repair
Repairs should only be carried out by
qualified personnel.
Repairs to the electrical equipment,
which are not specified in these operating
instructions, should only be carried out by
an electrician.
Switch off and unplug the appli-
ance before carrying out repairs
and servicing work on electrical
components.
F. Disposal instructions
The appliance should be disposed of by a
specialist firm. The specialist firm should
be informed of any hazardous residue in
the appliance.
F.1 Disposal instructions for
countries in the EU
To conserve and protect the environ-
ment, prevent environmental pollution and
improve the recycling of raw materials, the
European Commission adopted a directive
that requires the manufacturer to accept
the return of electrical and electronic appli-
ances for proper disposal or recycling.
Within the European Union appliances
with this symbol should not therefore be
disposed of in unsorted domestic waste.
For more information regarding proper
disposal please apply at your local authori-
ties.
EN
G. Technical data
G.1 Twister (No. 1826)
Mains voltage:
Power consumption:
Device fuse:
Speed:
LpA *) (idling):
Dimensions (WxHxD):
Weight:
G.2 Twister venturi (No. 1827)
Mains voltage:
Power consumption:
Device fuse:
Speed:
Connection pressure:
Air consumption, approx.:
LpA *) (idling):
Dimensions (WxHxD):
Weight:
*) sound pressure level in accord. with EN ISO 11202
H. Disclaimer
Renfert GmbH is not liable for claims for
compensation or claims under guarantee
if:
the product is used for purposes
other than those stated in the oper-
ating instructions
the product is modified in any way –
apart from modifications described
in the operating instructions
the product has not been repaired
by a specialist firm or original Ren-
fert replacement parts have not
been used
there is continued use of the prod-
uct despite obvious safety defects
or damage
- 12 -
230 V / 50-60 Hz
100-120 V / 50-60 Hz
180 VA
T4AL, 250VAC
100 - 450 1/Min
< 70 db(A)
105 x 285 x 235 mm
4,13 x 11,22 x 9,55 inch
5,2 kg (w./o. bowl)
230 V / 50-60 Hz
100-120 V / 50-60 Hz
180 VA
T4AL, 250VAC
100 bis 450 1/Min
5 - 6,5 bar
46 l/Min.
< 70 db(A)
105 x 285 x 235 mm
4,13 x 11,22 x 9,55 inch
4,0 kg (w./o. bowl)