Do not let go until the bowl stays
in place alone and vacuum level
bar has passed the halfway mark
(Fig. 24a)!
If the set vacuum is <100%, the
pump will switch off when it is
achieved.
If the set vacuum is <100% then
the pump can continue to run for a
short time, in order to reach the set
vacuum level exactly.
Twister venturi only
The reduced vacuum level (80%)
is achieved through an opened by-
pass. This is why it sounds similar
to when 100% vacuum is achieved.
8. Start the mixing process.
Press the control knob (Fig. 24b).
The remaining mixing time (count-
down) is displayed during the mixing
process.
By delaying the start of the mix-
ing process, a prevacuum can be
achieved.
9. The appliance beeps when the mixing
cycle has finished.
The time which has elapsed since the
end of the mixing cycle is shown in
the display.
10. Aerate bowl.
Hold the bowl!
Press the control knob.
The bowl will be released in a few
seconds.
11. Remove the mixing bowl
Tip:
Only mix the same type of material in
a given bowl. Residue form previous
mixing processes can have a negative
influence (e.g., silicon fails to harden,
etc.).
We recommend a separate bowl for
each type of material (plaster, invest-
ment, silicon).
Use the adhesive labels enclosed to
the mixing bowl.
2.6.1 A
BORT MIXING PROCESS
1. Stop the mixing process.
Press the control knob once.
The appliance will beep.
Mixing process being aborted
2. Aerate bowl.
Hold the bowl!
Press the control knob.
The bowl will be released in a few
seconds.
3. Remove the mixing bowl.
2.6.2 P
OWER CUT
Twister only
If a power cut should occur or the ap-
pliance is switched off during a mixing
operation, the vacuum will be maintained
and the bowl will stay on the device.
When the power returns or the
device is switched back on
again, the bowl will become ven-
tilated and then fall off.
Twister venturi only
In case of a power failure or if
the appliance is switched off,
the bowl will be vented and be
uncoupled.
2.7 Adjustment During the
Mixing Process
All the mixing parameters can be dis-
played in large-scale characters during the
mixing process if you press the relevant
parameter key.
The parameters can also be
changed during the mixing process
by pressing the relevant parameter
key and turning the control knob.
Changes made to the mixing pa-
rameter settings during the mix-
ing process will be applied to that
mixing process only and will not be
saved.