11.5

Electrical characteristics

Fig. 11.3 Electrical layout for outdoor and indoor connection.
Legend
1
Connector strip for the outdoor unit
2
Connector strip for the indoor unit
Power supply (V/Ph/Hz)
Supply section up to 25 meter (in mm 2 )
Indoor / Outdoor
Thermal-magnetic circuit breaker, type D (A)
Interconnection section up to 25 meter (mm 2 )
Inteconnect shielded cable or not (YES/NO)
EN
EN
Immediatte residual current protector (A)
Table 11.1 Electrical Characteristics
- 18 -
1
2
SDH 17-025 NW
SDH 17-035 NW
230/1/50
230/1/50
1.5
1.5
Indoor
Indoor
10
10
1.5
1.5
NO
NO
0.03
0.03
SDH 17-050 NW
SDH 17-065 NW
230/1/50
230/1/50
2.5
4
Indoor
Indoor
16
20
1.5
1.5
NO
NO
0.03
0.03