Filtral 5000: Assembly of the unit (Fig. S-V)
Bolt the pump (28) to the UVC water housing (26) using the union nut. Place the bio surface element (23) and gravel
bags (24) in the bottom strainer casing (2). Place the aeration stone (25) between the gravel bags (24). Ensure that the
hose is not kinked. Place the foam filters (3, 22) in the bottom strainer casing (2). Insert the UVC clarifying unit inclu-
ding the pump (20). Attach the top strainer casing (1) and press it onto the bottom strainer casing (2) until the clamps
engage in the bottom strainer casing. Important: Lead the connection cable (7) through the cable opening in the
bottom strainer casing (2) and route the cable such that pinching is avoided.
UVC lamp replacement (Fig. L-S)
Attention! Breakable glass.
Possible consequences: Injury of your hands caused by cuts.
Protective measures: Handle both quartz glass and UVC lamp with care.
Attention! Ultra-violet radiation.
Possible consequences: Eye or skin injury from burns.
Protective measures:
− Never operate the UVC lamp outside its housing.
− Never operate the UVC lamp in a housing that is defective.
− Open the UVC water housing (see "Opening and cleaning the UVC water housing").
− Remove the self-tapping screw (32).
− Unscrew the clamping screw (34) from the unit head (31) by turning counter-clockwise.
− Pull off the quartz glass (33) and the O-ring (35) while slightly turning the unit head (31).
− Pull out the UVC lamp (36) and replace.
Important: Only use lamps the identification and capacity data of which correspond to the information on the type
plate.
− Check the quartz glass (33) and the O ring (35) for damage.
− Insert the quartz glass (33) including the O ring (35) against the stop in the unit head (31).
− Tighten the clamping screw (34) clockwise up to the stop.
− Turn in and tighten the self-tapping screw (32).
− Close the UVC water housing (see "Closing the UVC water housing").
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Wearing parts
The UVC lamp, the different filters and the rotor are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.
- GB -
17