MALFUNCTIONS AND ADJUSTMENTS
The boiler adjustment system is constantly monitorized by an electronic control unit signalling the possible faults by
intermittant or continuos luminous warning signals to the leds situated on the front panel (fig.5) which are:
● Shutdown warning led (1)
● ON/OFF led (2)
● Fault warning led (3)
Constant light: Ignition shutdown
Fast flashing light: TST shutdown
Should the boiler shut down it must be reset by rotating function selector to the reset position A.
In fault conditions, the reset will occur after the fault has been repaired.
Legend:
On
Off
JP1
On LPG
On
(post-circ. off)
JP2
heating
Resistor R150 cut, floor heating temp. set to 30/40°C.
Resistor R150 uncut, heating temperature 35/80°C.
RLA
Slow ignition adjustment
Increase
R max
Max. heating power adjustment
Increase
Timer
Boiler timer adjustment
Increase
2
1
ON/OFF
Off METHANE
Off
post-circ.
on 2.5 minutes
A
60
3
40
90
0
120
4
0
3
1
2
Constant light: - no water circulation
- modulating coil
Fast flashing light: Sensor fault
Slowly flashing light: Air pressure switch
RLA
Rmax
34
fig.5
Timer
JP2
JP1
X