Water Connection; Gas - Nozzle Calibration - Lamborghini Caloreclima TREND 28 MBS W TOP Manual Para La Instalación Y El Mantenimiento

Caldera de gas con base y acumulador
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WATER CONNECTION

To prevent vibrations and noise in systems, avoid using pipes of small diameter, avoid using tight elbows and
sharp reductions in flow cross-section and hot flushing of the system is recommended to eliminate impurities
originating in pipes and radiators (particularly oil and grease) that could risk damaging the pump.

GAS - NOZZLE CALIBRATION

The boilers leave the factory calibrated and ready to operate with NATURAL GAS and LIQUID GAS.
For proper calibration, see the table below:
Gas type
NATURAL GAS
(G20-20mbar)
LIQUID GAS B
(G30-28/30mbar)
LIQUID GAS P
(G31-37mbar)
BURNER PRESSURE CURVES - OUTPUT
TREND 28 MBS
kPa
mbar
3,5
35
3
30
27,5
2,5
25
2
20
1,5
15
13
1
10
7,6
5,7
0,5
5
2,4
0,1
1
0
0
0
Slow ignition adjustment
3 mbar NATURAL GAS (28 MBS) - 3 mbar NATURAL GAS (32 MBS)
8 mbar LIQUID GAS (28 MBS) - 6 mbar LIQUID GAS (32 MBS)
Jets pressure mbar
32 MBS
28 MBS
min.
max.
min.
2,4
1,8
13
5,7
5
27,5
7,6
5,2
35
P 35
B 27,5
GN 13
10
15
20
25
30
Delivery
28 MBS 32 MBS
m
3
/h
m
max.
3,1
11,5
0,89
25,4
33
1,17
mbar
35
30
25
20
15
10
5
1
0
kW
35
Burner jets
28 MBS 32 MBS
3
/h
Ø mm.
3,47
1,25
1,01
0,77
1,32
0,77
TREND 32 MBS
5,2
1,8
0
10
15
20
30
L.C.V.
kcal/h
Ø mm.
8.550
1,35
29.330
0,80
0,80
22.360
P 33
B 25,4
GN
11,5
kW
25
30
35
Tabla de contenido
loading

Este manual también es adecuado para:

Trend 32 mbs w top

Tabla de contenido