Promax TV EXPLORER HD+ Manual De Instrucciones página 178

Explorador universal de tv
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

As well as the video carrier / noise level ratio (C/N) (41.0 dB in previous figure), the
frequency or channel (depending on the tuning mode selected) and the level of the video
carrier and video/audio ratio are also shown. When representing the spectrum by means
of pressing
[13] key, the NOISE cursor is automatically positioned to a side of the
carrier tuned. That is, the cursor will indicate the point where the value of the noise is
lower, whenever the C/N(AUTO) option is selected from the PREFERENCES
menu. If the C/N(MANUAL) option has been activated the frequency where noise level
will be measured will correspond to the position of the vertical discontinuous green-
coloured cursor that appears in the spectrum graph
In order to modify this frequency, press the measurement configuration
[17] key, to accede to the CONFIGURATION menu. By turning the rotary selector
[1], locate the NOISE cursor on the position of the marker using
option (see section "5.16.1 Markers") or directly enter the value of the new
MARKER
noise frequency by means of
Page 54
Figure 27.- Carrier-to-noise ratio measurement (C/N).
NOISE FREQ
Figure 28.- NOISE cursor. C/N (MANUAL).
USER'S MANUAL. TV EXPLORER HD+
[13].
option.
[22]
NOISE FREQ. TO
11/2013