Promax TV EXPLORER HD+ Manual De Instrucciones página 164

Explorador universal de tv
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Finally, select the SAT IF TEST application on UTILITIES
band, or the ATTENUATION TEST for terrestrial band and connect the generator to the
point where the antenna will be connected (signal source).
Press the
means of the Threshold Attenuation option is possible to adjust the maximum difference
between the pilots reference level from 5 to 50 dBμV.
Later, by means of the horizontal cursors
(see the following figure). Wait for some seconds until the calibration process for three
pilots is completed: MEASURING REF. is indicated on screen while this process is in
progress.
The calibration process must be carried out over the point of the installation which
is taken as reference, i.e. usually the headend. During this process is determined the
number of pilot frequencies to check, from one to three, in addition to the reference level
for pilots.
In order to determine the number of pilots, the equipment takes the higher found
level and verifies that the other pilots have a non lower level to the reference one plus
the defined threshold level. If the pilot agrees this condition it will show on screen.
The user can also define the pilot frequencies:
From the calibration screen, press the key
CONFIGURATION menu of the measure. The PILOTS function allows you to set pilot
signals manually. To do this, using the rotary selector
change it to MANUAL. You will see a menu where you can set the frequency of each of
the 3 pilot signals. If you want to return to the automatic generation of pilot signals,
change back PILOTS function to AUTO.
Page 40
[17] key to see on screen the measurement CONFIGURATION. By
Figure 16.- SAT IF Test. Satellite band.
USER'S MANUAL. TV EXPLORER HD+
[22] menu for SAT
[6] key, select the Calibrate function
[17] to show on screen the
[1] select that function and
11/2013
Tabla de contenido
loading

Tabla de contenido