Diagnostic Opening; Dirt On The Glass Plate; Displaying Images From The Sensors; Exhaust Gas On The Glass Plate - Bosch TTM 2104 Instrucciones De Servicio

Ocultar thumbs Ver también para TTM 2104:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

en
en
40 | TTM 2104/2204 | Diagnostic opening
9.

Diagnostic opening

9.1

Dirt on the glass plate

Fig. 13:
2-D image of dirt on the glass plate
Fig. 14:
3-D image of dirt on the glass plate
Fig. 15:
Checking a glass plate for dirt, e.g. oil film, etc.
!
The glass plate has a functional high-quality coating
that must not the destroyed. Damage leads to faulty
measurements.
i
Dirt on the glass plate leads to problems with
vehicle detection and tire detection. Incorrect or no
regional values are displayed.
i
The glass plate must therefore only be cleaned with
a paper towel moistened with clean water or the
glass squeegee supplied.
Depending on the degree of soiling, no regional
measured values are displayed and TTM 2104/2204 switches
to display of global measured values.
i
In the case of very severe soiling, faulty measured
values result.
"
To prevent observational errors, keep the diagnostic
opening and glass plate clean. If necessary, remove
coarse dirt and clean with water.
|
1 691 206 007
2017-06-19
9.2

Displaying images from the sensors

To assess the current camera situation, the images
for the current measurement can be displayed in the
browser at different lighting levels. To do this, enter
192.168.20.10/cmd/take-picture
Fig. 16:
Current camera situation
9.3

Exhaust gas on the glass plate

i
Under certain climatic conditions and when the
discharge opening of the vehicle's exhaust system
is directed downward, a deposit may form on the
glass plate of a module. This must be kept in mind
especially in the case of continuous testing.
Deposits on the glass plate can lead to observational
errors.
Fig. 17:
2-D image of exhaust gas on the glass plate, no tire
1 Exhaust
Fig. 18:
2-D image of exhaust gas on the glass plate, with tire
1 Exhaust
1
Fig. 19:
3-D image of exhaust gas on the glass plate, with tire
1 Exhaust
9.4

Moisture in the module

If moisture is detected in the module during a visual
check or by means of Live Viewer (see 9.2), the
following causes are involved:
R
Leaks
R
Module lying in water (capillary action)
R
Glass plate defective
R
No desiccant / desiccant saturated
In this case, the module must be replaced with a new
one.
in the browser.
1
1
Robert Bosch GmbH
Tabla de contenido
loading

Este manual también es adecuado para: