State "STAND-BY"
The device is switched on but no operating cycle is running. If power is interrupted while in "stand-by" mode,
when power is restored the device will be in the same state.

DEFROSTING AND THE EVAPORATOR FAN

2.14
The service controlled by relay K2 depends on parameter u0:
- If u0 = 0, the service controlled by relay K2 will be defrosting (electrical defrosting; the evaporator fan is
not controlled)
DURING BLAST CHILLING, operation of the evaporator fan depends on parameter F0
DURING STORAGE, operation of the evaporator fan depends on parameter F2
DURING DEFROSTING the evaporator fan is started.
In "stand-by" mode it is only possible to activate manual defrosting; if the service controlled by relay K2 is
the evaporator fan (parameter u0 = 1), during defrosting the evaporator fan will be switched on, and during
drip-draining, this will be switched off. To start defrosting in manual mode:
-
Ensure no procedure is running
- Press
for 4 s.
Defrosting is never activated during blast-chilling.
Defrosting occurs periodically during storage; it is possible to start defrosting manually.

VIEWING THE STATUS OF THE COMPRESSOR AND THE EVAPORATOR FAN

2.15
To view the compressor status:
- Ensure no procedure is running
- Press
the display will show the fi rst available label:
If the display shows "C-1", the compressor will be switched-on
If the display shows "C-0", the compressor will be switched off
If the display shows "C-P", compressor protection will be ongoing (parameters C0, C1, C2 and i7).
To view the status of the evaporator fan:
- Ensure no procedure is running
- Press
twice: the display will show the fi rst available label:
If the display shows "F-1", the evaporator fan will be switched on
If the display shows "F-0", the evaporator fan will be switched off
If the display shows "F-P", then evaporator fan deferred activation will be ongoing (parameter F8).
To exit the procedure:
- Press
until the display shows the ongoing status value, or leave for 15 s.
If the service controlled by relay K2 is defrosting (parameter u0 = 0), labels "F-1", "F-0" and "F-P" will not be
displayed.