Tripp-Lite B020-008-17 El Manual Del Propietario página 19

Ocultar thumbs Ver también para B020-008-17:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

7. oSD ( on-Screen Display) operation
F4 Administrator (ADM)
F4 is an Administrator-only function. It allows the Administrator to configure and control the overall
operation of the OSD. To change a setting double-click it or use the Up / Down Arrow Keys to move the
highlight bar to the item and press [Enter].
After an item has been selected, a submenu with additional choices will appear. Either double-click the
desired choice, or move the Highlight Bar to it and press [Enter]. An icon appears beside the selected
choice to identify it. The settings are explained in the following table:
Setting
SeT USeRNAMe
AND PASSWoRD
SeT LogoUT
TIMeoUT
eDIT PoRT NAMeS
ReSToRe
DeFAULT VALUeS
CLeAR THe NAMe
LIST
ACTIVATe BeePeR
SeT QUICK VIeW
PoRTS
Function
Sets the Usernames and Passwords for the Administrator and Users:
One Administrator and four User passwords can be set.
After selecting one of the User fields or the Administrator field, a screen allows you to key in
your password. The password may be up to 12 characters long, and can consist of any
combination of letters (both upper and lower case) and numbers (A - Z, a - z, 0 - 9), as well as
commas, %, *, and parentheses.
Key in the Username and Password for each individual and press [Enter]. Use the backspace
key to erase letters or numbers in order to modify or delete a Username and/or Password.
If the console is left idle for the amount of time set with this function, the Operator will be
automatically logged out. A login is necessary before the console can be used again. This lets
other Operators access the computers if the original has forgotten to log out. To set the timeout
value, key in a number from 1 - 180 minutes, then press [Enter]. If the number is 0 [zero], this
function is disabled.
Default is 0 (disabled).
Every port can be given a name to help identify the attached computer. The Administrator can
use this function to create, modify, or delete port names. To edit a port name: click the desired
port, or use the Navigation Keys to move the highlight bar to it, then press [Enter].
Key in the new Port Name, or modify/delete the old one. The maximum number of characters
allowed for the Port Name is 12. Legal characters include:
All alpha characters: a - z; A - Z
All numeric characters: 0 - 9
+ - / : . and Space
Case does not matter as the OSD displays the Port Name in all capitals no matter how they
were entered.
When finished editing, press [Enter] to have the change take effect. To abort the change, press
[Esc].
Undo all changes and return to the original default settings using this function. The only
exception is the Names settings assigned to the Ports. Note: Passwords are not affected.
This function is similar to Restore Default Values. The difference is that it also clears the Names
settings along with undoing all changes and returning the setup to the original default settings.
Choices are Y (for Yes), or N (for No). When activated, the beeper sounds whenever a port is
changed; the Auto Scan function is activated (see F7 SCAN, page 21); an invalid entry is made
on an OSD menu; the default is Y (activated).
Allows the Administrator to select which Ports are to be Quick View ports. To select/deselect a
port as a Quick View Port, double-click the desired port, or use the Navigation Keys to move
the highlight bar to it, then Press [Enter].
An arrow is displayed in the QV column on the Main Screen to indicate that a port has been
selected as a Quick View Port. The arrow disappears when a port is deselected. If one of the
Quick View options is chosen for the LIST view (see F2 LIST, page 17), only a Port that has
been selected here will display on the List.
If one of the Quick View options is chosen for Auto Scanning (see SCAN/SKIP MODE,
page 14), only a Port that has been selected here will be Auto Scanned. The default is for no
ports to be selected.