Periodic Reminder Messages
Press the "Mode" button to reset a displayed reminder)
Message Frequency
rPH
Every 7 days
rSA
Every 7 days
rCL
Every 30 days
rtg
Every 30 days
rdr
Every 90 days
RCO
Every 180 days
RCH
Every 365 days

Diagnostic Messages

Message
No message on display. Power has
been cut off to the spa.
OHH
"Overheat" - The spa has shut down.
One of the sensors has detected 47.7˚C
at the heater.
OHS
"Overheat" - The spa has shut down.
One of the sensors has detected that
the spa water is 43.3˚C.
ICE
"Ice"
-
detected.
Sna
Spa is shut down. The sensor that is
plugged into the Sensor "A" jack is not
working.
Snb
Spa is shut down. The sensor that is
plugged into the Sensor "B" jack is not
working.
Sns
Sensors are out of balance. If this is
Alternating with the temperature, it
may just be a temporary Condition. If
the display shows only this message
(periodically blinking), the spa is shut
down.
HFL
A substantial difference between the
temperature sensors was detected. This
could indicate a flow problem.
2009 Portable Spa Owner's Manual
LTR20091001, Rev. A
Action Required
Test and adjust chemical levels per manufacturer's instructions.
Test and adjust chemical levels per manufacturer's instructions.
Remove, clean, and reinstall filter per manufacturer's instructions.
Test & reset GFCI per manufacturer's instructions. Drain and refill spa per
manufacturer's instructions.
Drain and refill spa per manufacturer's instructions.
Clean and condition spa cover
Install New Bio-Clean™ Filter
Meaning
Potential
freeze
condition
Action Required
The control panel will be disabled until power returns.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. Once the heater has cooled,
reset by pushing any button. If spa does not reset, shut
off the power to the spa and call your dealer or service
organization.
DO NOT ENTER THE WATER. Remove the spa cover and
allow water to cool. At 41.6˚C, the spa should automatically
reset. If spa does not reset, shut off the power to the spa
and call your dealer or service organization.
No action required. The pumps and the blower will
automatically activate regardless of spa status.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organization.
If the water level is okay, make sure the pumps have
been primed. If problem persists, contact your dealer or
service organization.