Promax PROLITE-40 Manual De Instrucciones página 114

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

The fiber can be reset as normal, but when setting gap, "Setting gap" is displayed
on screen and after a while "Reload fiber" is displayed on screen.
Solutions:
1.- Raise the windshield, left and right clamps. The checking steps as follows.
2.- Check whether broken fiber exists.
3.- Check whether cleaved length is too short.
4.- Check whether fiber matches with V-groove.
When calibrating automatically, fiber moves up and down, the screen's display
stops at "Adjust core".
Solutions:
1.- Check whether the position warp between X and Y directions' surface is
less than 1cm. (screen displays size) If not, return PROLITE-40 factory to
fix, otherwise operating as follows.
2.- Check whether bare fiber is clean.
3.- Clean the dust of V-groove.
4.- See Appendix E: Clean the V groove and fiber.
The fiber can be reset as normal, but when setting gap, "Setting gap" is displayed
on screen and after a while "Bad left fiber's surface" is displayed.
Solutions:
1.- Observe fiber picture in screen, if the quality of left fiber's surface is bad you
can remake surface and try again.
2.- Observe fiber picture in screen, if the quality of left fiber's surface is good,
maybe the value of "Setting surface" is too small, if you want to keep on
working you can increase it.
3.- After "Bad left fiber's surface" is displayed, the screen becomes dark.
(1)
(2)
Page 40
Make sure that windshield is covered well.
Raise windshield, check whether the pipe is dent, and then
manage it.