6 INSTALLATION
6.1 LEVELLING THE STOVE
using a spirit level (Fig. 6.1).
A B = Spirit level
6.2 SYSTEM CONNECTIONS
6.2.1 Electrical connection
The stove is connected to the electrical system simply using the plug supplied.
The electrical connection (plug) must be easily accessible when the stove is installed.
If the power cord is damaged it must be replaced by the technical service or a
6.2.1.1 Earth
accordance with legislation in force (Fig. 6.2).
6.2.2 Connection to an external timer thermostat
The stove can be connected to an external timer thermostat that switches the stove
on or off according to the set temperature.
When the set temperature is reached the thermostat opens the circuit and
consequently switches off the stove.
The external thermostat is connected to the two terminals on the rear of the stove,
thermostat contacts.
while the timer thermostat is in "call" status. This operation is also required in the
event of power failures or if the stove is switched off manually.
To avoid overlapping the working time bands, it's recommend to disable (set to OFF)
the stove's timer (see par. 10.1).
6.2.3 Operation with room probe
In certain circumstances the stove may need to modulate operation based on the
In this case reverse the connections (T01 and T05) on the electronic board as
described in Fig. 6.3. To do this, access the board by removing the rear panel on
the stove.
6.3.
6.2.4 Connection to a storage tank with coil
coil.
probe socket on the storage tank.
6.3.
6.2.5 Connection to a storage tank without coil
The stove can be used to maintain the temperature inside a storage tank without
coil.
probe socket on the storage tank.
40/140
INSTALLATION
1 following the instructions shown in the
2 following the instructions shown in paragraph
INSTALLATION MANUAL
- cod. 004771060 - 09/2011 - Palazzetti - PN - Italy
Fig. 6.1
Fig. 6.2
2
3
5
6
4
Fig. 6.3