Leave enough clearance for maintenance work.
materials (x) is observed, as shown on the pipes
Pi
Pp = Protezione pavimento

5.4 COMBUSTION AIR

During operation the stove takes in a certain amount
of air from the room where it's installed (except for
the "Ermetica" series products that can take in air
directly from the outside); this air must be replaced
through an opening to the outside from the room
(Fig. 5.3 - PA = Fresh air vent).
If the wall behind of the stove is an outside wall,
make an opening for drawing in combustion air
dimensions shown on the product data sheet at
the end of this booklet.
A permanent non-closable vent cover must be
placed on the outside of the opening; in especially
windy areas or places exposed to bad weather,
install rain and wind protection elements.
Make sure that the air vent is located in such a way
that it can't be accidentally obstructed.
If it's not possible to make a fresh air opening in
the wall behind the stove (not a perimeter wall),
an opening must be made on the wall in the room
where the stove is installed that faces the outside.
If no fresh air opening can be made in the room, it
two rooms are connected by a ventilation grill (Fig.
5.4 - C = Shutter box, G = Grill, S = Shutters)
Standard UNI 10683 prohibits combustion air being
drawn in from garages, combustible material stores
If there are other heating appliances in the same
room, the fresh air vents must guarantee the
required volume of air for correct operation of all
the appliances.
If one or more exhaust fans (range hoods) are
installed and operating in the room where the stove
is located, combustion problems may occur due to
a lack of combustion air.
"E
"
RMETICA
SERIES STOVES
The "Ermetica" series pellet stoves allow the
following possible installation alternatives:
-
ducted combustion air using a coaxial pipe to
consequently no fresh air vent is needed in the
room (Fig. 5.5 A, B=Air intake C, D=Flue gas
outlet);
-
connect the stove combustion air intake to the
fresh air opening using a special pipe (Fig. 5.6).
INSTALLATION MANUAL
INSTALLATION
- cod. 004771060 - 09/2011 - Palazzetti - PN - Italy
Pi
Pi
150 cm
Pp
C
G
Fig. 5.2
PA
Fig. 5.3
S
Fig. 5.4
37/140