Toxic Gas Measurements
The Orion plus Multigas Detector can be equipped to detect specific
toxic gases.
When the Low alarm setpoint is reached for any toxic gas:
•
Alarm sounds and Alarm lights flash
•
Lo Alarm indication and gas label above the concentration flashes;
all other non-alarming gas readings move to the background.
To silence the alarm, press the RESET button.
NOTE: The alarm will stay silent if the alarm condition has cleared.
When the toxic gas indication reaches the High Alarm Setpoint, the:
•
Alarm sounds and Alarm lights flash at higher frequency
•
Hi Alarm indication and gas label (located above the concentration)
flashes; all other non-alarming gas readings move to the
background.
NOTE: This alarm cannot be reset with the RESET button until the
condition is cleared.
If the Oxygen or Toxic Gas alarm condition is reached while
using the instrument as a personal or area monitor, leave the
area immediately; the ambient condition has reached a pre-
set alarm level. If using the instrument as an inspection
device, do not enter the area without proper protection.
Failure to follow this warning will cause over-exposure to
toxic gases, which can result in serious personal injury or
death.
Viewing Optional Displays
•
Press the PAGE button to move to Minimum Readings (MINIMUM).
•
This page shows the lowest level of oxygen recorded by the
Orion plus Multigas Detector since Turn-ON.
3-10
" WARNING