Chapter 3 Basic Operation
Setting up the warning value
PJ Network Manager provides a function to display
the alert when the use time of the setting item
reaches a specified setting time. The available set-
ting items (use time) depend on the target equip-
ment.
1
Select a target on the status list with right-click.
0 When setting multiple targets together, select tar-
gets by pressing "Shift" or "Control" key.
2
Select Warning value setting on the popup
menu. The setting window will appear as the
right figure.
3
Check Warning time check box. The setting
items are activated. Select a setting item and click
Edit. Another setting window appears.
4
Enter the threshold value of selected item and
then click OK. The setting window will disappear.
5
Set up a warning value for remaining items if avail-
able and then click OK. The setting window will
disappear.
0 To disable the warning value, clear Warning time
check box.
0 When selecting multiple targets, the value set to the lowest target on the status list is displayed as
the current setting time. Up to 99,999 hours can be set for the use time. The warning value is stored
in the management file.
Starting target monitoring
1
Click
on the tool bar to start monitoring the target.
2
PJ Network Manager starts polling the target in sequence from the top of the status list
and displays the results on the status list.
12
(Example of the set up window)
PJ Network Manager for Windows