Christie LX1750 Manual De Instrucciones página 26

Ocultar thumbs Ver también para LX1750:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 95
Description of warning value
Warning Column
Connect
Power status
Input signal status
Inside Temperature status (A to
C)
External Temperature status
Lamp status
Lamp time
Filter status
Filter time
(Auto play error)
(WarningOnConstantModeFor
Brightness)
0 The column order and width of the event log window are saved to the registry of the computer.
0 Up to 1000 of events can be stored. If it exceeds 1000 events, the oldest event is deleted and the
latest event is added. The event log can be saved to the management file.
PJ Network Manager for Windows
020-000640-01 Rev.1 (11-2013)
Description of Event, Type, Warning column, Warning value
Warning Value
Un-connected
Connected *
Acquisition error
Power failure
TemperatureError
Normal (AfterTempError)
RS232CFailure
Power management
Shutter management
LampFailure
Normal(Standby) *
Normal(OnCoolingDown) *
SignalsInterrupted
SignalsInputted *
Abnormal
ON *
Failure
Replace
(lamp time)
Clogged
Warning
(filter time)
n/a
n/a
0 The warning value with "*" in the above table shows the
event when the alert has cleared, alert type is "OFF".
Description
Projector has been disconnected from the network
Projector has been connected to the network
PJ Network Manager could not acquire the MIB information
from the equipment
Projector turned off due to the power failure of the projector
The projector turned off due to temperature error
Normal after temperature error occurred
The RS-232C communication error occurred
The power management function turned projector lamp off
The shutter management function turned projector lamp off
Lamp failure occurred
Projector turned into standby normally
Cooling down normally due to projector turned off
The signal was interrupted
The signal was inputted again
The projector turned off when the temperature was
abnormally high
When the lamp is on
When the lamp failed to ignite
It reached lamp replacing time
The user setting for lamp replacing time has been reached.
Filter has been clogged
Filter is close to clogging
The user setting for filter time has been reached.
An error occurred during the auto image display
The brightness (Current value) continuously goes down a
certain rate from the value in Constant mode.
25
Tabla de contenido
loading

Tabla de contenido