LEONARDO
is a combustion safety and control system which
®
allows optimal performance in all conditions thanks to two sen-
sors measuring the pressure level in the combustion chamber
and smoke temperature. The detection of and subsequent opti-
misation of these two parameters is continuous in order to cor-
rect operation anomalies in real time. The LEONARDO
offers constant combustion, automatically regulating the draft
based on the characteristics of the chimney fl ue (bends, length,
shape, diameter, etc..) and environmental conditions (wind, hu-
midity, atmospheric pressure, installations at high altitude, etc.).
The standards for installation must be respected. LEONARDO
system is also able to recognise the type of pellets and automa-
tically djust the fl ow moment by moment to ensure the required
level of combustion.

SAFETY DEVICES

THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the boiler on and off and controls its operation based on
defi ned parameters.
VACUUM GAUGE (electronic pressure sensor):
positioned on the smoke extractor, which detects the vacuum
value (compared to the installation environment) in the combu-
stion chamber.
WATER SAFETY THERMOSTAT:
Trips when the temperature inside the boiler is too high.
It stops pellet loading, causing the boiler-fi replace to go out.
Reset manually (see pag. 26).
TANK SAFETY THERMOSTAT:
Located on the system that loads the pellets from the hopper.
Trips when the temperature inside the boiler-fi replac is too high.
It stops pellet loading, causing the boiler-fi replace to go out.
SERIAL PORT
The Dealer can install an optional on the AUX (located on the
electronic board), outlet for controlling the process of switching
on and off (e.g. telephone remote, local thermostat), located at
the rear oh the boiler.
Can be connected via special optional trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR 2032
battery).
Its malfunction is indicated with the following messages: (not
considered a defect but due to normal wear-and-tear): "Battery
check". For more detailed information, please contact the DEA-
LER who has performed the fi rst 1st ignition.

ELECTRONIC EQUIPMENT

system
®
®

ELECTRONIC CIRCUIT BOARD

ACS (hot sanitary
water) request probe
bus 485 socket
RS232
socket
RS 232
consolle
Boiler
circulator
(optional)
Screw 2
Smoke expulsion motor
- 27
-
Thermocouple
Feed screw
T° smoke
warning probe
Optional
Water
boiler
outlet
probe
probe
RPM smoke
Vacuum gauge
RPM Screw 1
Vacuum gauge
RPM Screw 2
Thermocouple
Reading points
battery CR 2032
FUSE 2AT
rear socket
RES ingnition element
Screw 1
Outlet pump
230 Vac Power
50Hz +/- 10%