Troubleshooting
Always remove the battery before carrying out any work on the power tool.
Condition
Machine does not run when switched on
RMA 370
Cause
No electrical contact between power tool
and battery
Battery discharged
(1 light emitting diode on battery flashes
green)
Battery too hot / too cold
(1 light emitting diode on battery glows
red)
Fault in battery
(4 light emitting diodes on battery flash
red)
Fuse key not fitted
Fault in fuse key
Power tool too hot
(3 light emitting diodes on battery glow
red)
Electromagnetic interference or fault in
power tool
(3 light emitting diodes on battery flash
red)
Motor overloaded by high or damp grass Do not start motor in high grass, adjust
Mower housing blocked
Moisture in power tool and/or battery
Remedy
Remove battery, check contacts and refit
battery
Charge the battery
Allow battery to cool down / at tempera -
tures of about 59°F - 68°F (15°C - 20°C),
allow battery to warm up slowly
Take the battery out of the power tool
and refit it. Switch on the power tool – if
the light emitting diodes still flash, the
battery is faulty and must be replaced.
Fit the fuse key
Replace fuse key
Allow power tool to cool down
Take the battery out of the power tool
and refit it. Switch on the power tool – if
the light emitting diodes still flash, the
power tool is faulty and must be checked
1)
by a servicing dealer
.
cutting height to suit conditions
Clean mower housing
Allow power tool/battery to dry
English