EN
3.3 Technical data
NOTE!
Filter data is for standard filters. Other filters may be equipped.
Table 3.1 Technical data FlexPAK 800
FlexPAK 800
Effect
Mains voltage/frequency
Maximum flow
Flow at -20 kPa
Maximum vacuum
Main filter area
Main filter material
Material filtration effi-
*
ciency
Weight
Inlet/outlet diameter
Sound level
Maximum ambient tem-
perature
Process air temperature
Relative humidity
Compressed air
Material recycling
Control Filter area
Control Filter material
* According to DIN EN/IEC 60335-2-69.
18
FlexPAK 800/1000
18.5 kW (25 hp)
230 V±10%/50–60 Hz
3
1,300 m
/h (765 cfm)
3
800 m
/h (470 cfm)
-35 kPa (-5.1 PSI)
2
6 m
(64.5 sqft)
Polypropylene
Dust class M
439 kg (968 lb)
150/160 mm
(7.87/6.29")
70 dB(A)
-10 – +40 °C (14–104 °F)
0 – +60 °C (0–140 °F)
Max. 85%
6–7 bar (87–102 PSI)
93.6% per weight
x12 m² (1x129 sqft)
Polyester
18.5 kW (25 hp)
400 V±10%/50–60 Hz
3
1,300 m
/h (765 cfm)
3
800 m
/h (470 cfm)
-35 kPa (-5.1 PSI)
2
6 m
(64.5 sqft)
Polypropylene
Dust class M
439 kg (968 lb)
150/160 mm
(7.87/6.29")
70 dB(A)
-10 – +40 °C (14–104 °F)
0 – +60 °C (0–140 °F)
Max. 85%
6–7 bar (87–102 PSI)
93.6% per weight
x12 m² (1x129 sqft)
Polyester
21.5 kW (29 hp)
460 V±10%/50–60 Hz
3
1,300 m
/h (765 cfm)
3
800 m
/h (470 cfm)
-35 kPa (-5.1 PSI)
2
6 m
(64.5 sqft)
Polypropylene
Dust class M
439 kg (968 lb)
150/160 mm
(7.87/6.29")
70 dB(A)
-10 – +40 °C (14–104 °F)
0 – +60 °C (0–140 °F)
Max. 85%
6–7 bar (87–102 PSI)
93.6% per weight
x12 m² (1x129 sqft)