Technical And Electrical Data; Technical Data; Electrical Data - Nederman E-PAK 150 DX Manual De Instrucciones

Ocultar thumbs Ver también para E-PAK 150 DX:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 115
5.3

Technical and electrical data

5.3.1

Technical data

Table 5-1: Technical data contains technical data for the E-PAK DX high
vacuum units.
Figure 25 shows the fan characteristics diagram.
Table 5-1: Technical data
E-PAK 150 DX
Operating air flow at
110 m³/h (64.7 cfm)
15 kPa
Filter area: main filter/
3.4/1.5 m
control filter
Filter material: main
Conductive polyester/polyester
filter/control filter
Ambient temperature
-10–+40 °C (14–104 °F)
Process air
0–60 °C (32–102 °F)
temperature
Compressed air:
requirements
6–10 bar (87–145 PSI)
consumption
0.5 NL (0.13 gal)/cleaning pulse
Dimension, inlet
Flanged Ø 100 mm (3.937 in)
Dimension, outlet
Ø 105 mm (4.13 in)
Collector volume
50 litres (13.21 gal)
Weight
209 kg (460.8 lb)
Dimensions
See Section 5.2 Dimensions
Material recycling
Approximately 95 percent per weight
Sound level
<70 dB(A)
5.3.2

Electrical data

'Table 5-2: Electrical data' contains electrical data for the E-PAK DX high
vacuum units. For the location of the motor and starter cable areas (items Z, V
and X in the table), see Figure 22 and Figure 24.
Table 5-2: Electrical data
Motor
Voltage
Nom.
power
and
current
(kW/hp)
frequency
(A)
(V)/(Hz)
E-PAK 500 DX
12.5
230/50
47.5
13
400/50
27
15.3/20
208/60
55.0
14.5/19
230/60
49.6
15.3/20
440/60
27
15.3/20
460/60
26.0
15.3/20
575/60
20.4
E-PAK 300 DX
5.5
230/50
23.0
5.5
400/50
13.6
6.3/10
208/60
24.5
6.3/10
230/60
22.5
(36.6/16.1 sqft)
2
F1
F2 & F3,
Recom.
slow (A)
mains
fuses,
slow (A)
50
6
35
6
60
6
60
6
35
6
35
6
25
6
25
6
16
6
30
6
30
6
E-PAK 150 DX/300 DX/500 DX
E-PAK 300 DX
290 m³/h (107.7 cfm)
3.4/1.5 m
(36.6/16.1 sqft)
2
Conductive polyester/polyester
-10–+40 °C (14–104 °F)
0–60 °C (32–102 °F)
6–10 bar (87–145 PSI)
0.5 NL (0.13 gal)/cleaning pulse
Flanged Ø 100 mm (3.937 in)
Ø 105 mm (4.13 in)
50 litres (13.21 gal)
250 kg (551.2 lb)
See Section 5.2 Dimensions
Approximately 95 percent per weight
<70 dB(A)
F4,
F5 & F6,
S1F Over-
slow (A)
fast (A)
load relay
setting
(A)
4
1
27.4
4
1
15.6
4
1
31.8
4
1
28.6
4
1
15.6
4
1
15.0
4
1
11.8
4
1
13.3
4
1
7.9
4
1
14.1
4
1
13.0
E-PAK 500 DX
500 m³/h (942 cfm)
3.4/1.5 m² (36.6/16.1 sqft)
Conductive polyester/polyester
-10–+40 °C (14–104 °F)
0–60 °C (32–102 °F)
6–10 bar (87–145 PSI)
0.5 NL (0.13 gal)/cleaning pulse
Flanged Ø 100 mm (3.937 in)
Ø 105 mm (4.13 in)
50 litres (13.21 gal)
335 kg (734 lb)
See Section 5.2 Dimensions
Approximately 95 percent per weight
<70 dB(A)
Min. cable
Cable
Cable
area to
area
area
motor
inside
inside
(mm
) Z
starter
starter
2
(mm
) V
(mm
2
6.0
2.5
16.0
2.5
2.5
6.0
6.0
4.0
16.0
6.0
4.0
16.0
2.5
2.5
10.0
2.5
2.5
10.0
2.5
2.5
10.0
2.5
2.5
4.0
2.5
2.5
4.0
2.5
2.5
4.0
2.5
2.5
4.0
EN