6.2.2 Bag Replacement Switch Activated
EN
The bag replacement switch (SC2) is activated. It shows the maximum allowed time to replace the dust bag, and
how much time is left to replace the dust bag and turn off the bag replacement switch before the unit is put into
Off mode.
If this warning is activated, the light in the Standby/Running button is lit for two seconds and then again in 2
seconds. This 2/2 on/off sequence continues until the warning is reset.
Bag Replacement
Switch Activated
Time to Unit
Stop
Max Time
6.3 Alarms
If an alarm is activated, the unit goes into Off mode until the problem is corrected.
If an alarm message is displayed in the PLC display, the light in the Standby/Running button flashes one second
on, one second off. This 1/1 on/off sequence continues until the problem is corrected and the alarm reset. See
also the PLC Settings Manual and the Installation and Service Manual.
6.3.1 External Fire Alarm Explosion Detected
Establish procedures to follow in order to prevent this alarm from being activated, and for when the
alarm is activated. Procedures should follow the current ATEX directive as well as local rules and regula-
tions.
An external fire alarm is activated or a Relief Panel Sensor (RPS) is connected and has detected an explosion.
• Press 'OK' to reset the alarm.
E x t e r n a l
F i r e A l a r m o r
E x p l o s i o n
D e t e c t e d
Th 11:23
Reset OK==>
26
FlexPAK 800/1000
02:00m
30:00m
ESC
ESC
Stop: The remaining time to replace the dust bag be-
fore the unit is put into Off mode.
MaxTime: The maximum amount of time allowed to
replace the dust bag.
OK
OK