Technical Data; Fuses - Nederman FlexVAC Manual De Usuario

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 86
3.3 Technical data
Table 3.1 Technical data
FlexVAC
Power
Mains voltage/frequency
Maximum flow
Flow at -15 kPa
Flow at -20 kPa
Maximum vacuum
Weight
Inlet/outlet diameter (flanged)
Sound level
Ambient temperature range
Process air temperature
Relative humidity
Material recycling
Maximum installation altitude
Corrosion class according to ISO 12944-2
Supply voltage to external equipment
Protection class
3.4 Fuses
Table 3.2 Fuses
Fuse
Main fuse F1, 400 V
Transformer, primary fuse F2 and F3
Transformer, secondary protection
F4
F5
* General size, see also included electrical diagrams.
FlexVAC
18,5 kW (25 hp)
400 V±10%/50–60 Hz
3
1300 m
/h (765 cfm)
3
1000 m
/h (588 cfm)
3
800 m
/h (470 cfm)
-35 kPa (-5,1 psi)
250 kg (551 lb)
100/160 mm (3,94/6,29")
70 dB(A)
0 – +40 °C (32–104 °F)
0 – +60 °C (32–140 °F)
Max. 85%
93,6% per weight
1000 m above sea level
C2 according to ISO 12944-2
24 VDC ±15%
IP42
Size
35 A
*
0,8 A
*
50 mA
*
1 A
Type
Slow mains fuses
Slow fuses, 10,3×38
PTC resistor
Fast, 5×20
Slow, 5×20
EN
15
loading