Product Description And Specifications; Intended Use; Product Features; Technical Data - Bosch GPL 5 Professional Manual De Instrucciones

Ocultar thumbs Ver también para GPL 5 Professional:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
OBJ_BUCH-815-002.book Page 9 Tuesday, March 13, 2012 2:43 PM
The measuring tool is provided with a warning label in
English (marked with number 5 in the representation
of the measuring tool on the graphics page).
IEC 60825-1:2007-03
< 1 mW, 635 nm
Do not direct the laser beam at persons or animals and
do not stare into the laser beam yourself. This measur-
ing tool produces laser class 2 laser radiation according to
IEC 60825-1. This can lead to persons being blinded.
Do not use the laser viewing glasses as safety goggles.
The laser viewing glasses are used for improved visualisa-
tion of the laser beam, but they do not protect against laser
radiation.
Do not use the laser viewing glasses as sun glasses or in
traffic. The laser viewing glasses do not afford complete
UV protection and reduce colour perception.
Have the measuring tool repaired only through quali-
fied specialists using original spare parts. This ensures
that the safety of the measuring tool is maintained.
Do not allow children to use the laser measuring tool
without supervision. They could unintentionally blind
other persons or themselves.
Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids,
gases or dusts. Sparks can be created in the measuring
tool which may ignite the dust or fumes.
Holder
Keep the holder 8 away from cardiac
pacemakers. The magnets 12 generate a
field that can impair the function of cardiac
pacemakers.
Keep the holder 8 away from magnetic data medium
and magnetically-sensitive equipment. The effect of the
magnets 12 can lead to irreversible data loss.
Product Description and
Specifications
Please unfold the fold-out page with the representation of the
measuring tool and leave it unfolded while reading the operat-
ing instructions.

Intended Use

The measuring tool is intended for determining and checking
horizontal and vertical lines as well as plumb points.
Bosch Power Tools

Product Features

The numbering of the product features shown refers to the
illustration of the measuring tool on the graphic page.
1 Exit opening for laser beam
2 Latch of battery lid
3 Battery lid
4 On/Off switch
5 Laser warning label
6 Tripod mount 1/4"
7 Serial number
8 Holder
9 Locking screw for holder
10 Screw holes of holder
11 Opening for strap attachment
12 Magnets
13 1/4" tripod mount on holder
14 5/8" tripod mount on holder
15 Measuring plate with stand*
16 Protective pouch
17 Laser viewing glasses*
18 Tripod*
* The accessories illustrated or described are not included as
standard delivery.

Technical Data

Point Laser
Article number
Working range
Levelling Accuracy
Self-levelling range (typical) along-
side the
– longitudinal axis
– lateral axis
Levelling duration, typically
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Tripod mount
Batteries
Operating life time, approx.
Weight according to
EPTA-Procedure 01/2003
Dimensions (length x width x height)
Degree of protection
The measuring tool can be clearly identified with the serial number 7 on
the type plate.
English | 9
GPL 5
3 601 K66 2..
30 m
±0.3 mm/m
±5°
±3°
<4 s
–10 °C...+40 °C
–20 °C...+70 °C
90 %
2
635 nm, <1 mW
1/4"
3 x 1.5 V LR06 (AA)
24 h
0.25 kg
104 x 40 x 80 mm
IP 5X
1 609 929 S07 | (13.3.12)
Tabla de contenido
loading

Tabla de contenido