Technical data

Mains voltage
Nominal current
Rated power
Protection class
Large waste container capacity
Cutting process for paper
Working width
Cutting capacity

Overheating protection

This appliance is fitted with overheating protection . If the motor overheats due to
overloading, the appliance switches itself off automatically and the "Overheat"
lamp 8 lights up permanently red until the motor has cooled down sufficiently .
If this occurs, proceed as follows:
WARNING – RISK OF INJURY!
Remove the power plug from the wall socket to avoid unintended starting
of the appliance .
Switch the appliance off by moving the switch 9 to the middle position "OFF" .
Empty the waste containers 2/4 .
Allow the appliance to cool down .
Put the mains plug back into the socket .
Switch the appliance on, by moving the switch 9 into the "AUTO" position .
The "Power" lamp 7 lights up permanently green .
The "Overheat" lamp 8 is off when the appliance has cooled down suf-
ficiently .
We recommend that you let the appliance cool down for about 30 minutes after
3 minutes of operation .
UAV 250 A2
220 - 240 V ~ (AC), 50 Hz
approx . 1 .2 A
250 W
II /
(double insulation)
21 litres
Cross-cut,
5 x 18 mm particles
Safety level P‒4
220 mm
2
10 sheets (80 g/m
)