11) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
11.1) TESTED DEVICES Fig. J
12) CLOSING LIMIT SWITCH PRESSURE Fig. K
13) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER Fig. L
Refer to specific manual.
ACCES TO MENU: Fig. 1
PARAMETERS MENU (para )
(TABLE "A" PARAMETERS)
LOGIC MENU (logic)
(TABLE "B" LOGIC)
RADIO MENU (RADIO)
Logic
Description
Add Start Key
add start
associates the desired key with the Start command
Add 2ch Key
add 2ch
associates the desired key with the 2nd radio channel command
Read
Checks a key of a receiver and, if memorized, returns the
read
number of the receiver in the memory location (from 01 to
63) and number of the key (T1-T2-T3 or T4).
Erase List
WARNING! Erases all memorized remote controls from
erase 64
the receiver's memory.
Read receiver code
cod RX
Displays receiver code required for cloning remote controls.
ON = Enables remote programming of cards via a previously
memorized W LINK transmitter. It remains enabled for
3 minutes from the time the W LINK remote control is
v
last pressed.
OFF=W LINK programming disabled.
-
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
TABLE "A" - PARAMETERS MENU - (PARA )
Logic
min. max. Default
0
120
40
tca
open delay
0,0 10,0
3
ti e
cls delay
0,0 60,0
3
ti e
ot1
1
99
50
torque
ot 2
1
99
50
torque
15
50
15
slov speed
50
99
99
op speed
50
99
99
cl speed
5
50
5
dist. slovd
10
99
40
ap. parz.
INSTALLATION MANUAL
Definition
Personal
Automatic Closing Time
Opening delay time
Closing delay time
Motor 1 torque
Motor 2 torque
Slow-down speed
Speed during opening
Speed during closing
Slow-down space
Pedestrian opening
In the event of manual programming, the first transmitter assigns the RECEIVER'S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced
features:
• Cloning of master transmitter (rolling code or fixed code)
• Cloning to replace transmitters already entered in receiver
• Transmitter database management
• Receiver community management
To use these advanced features, refer to the universal handheld programmer's
instructions and to the CLONIX Programming Guide, which come with the uni-
versal handheld programmer device.
LANGUAGE MENU (language)
Used to set the programmer's language on the display.
DEFAULT MENU (default)
Restores the controller's default factory settings.
AUTOSET MENU (Autoset)
See Fig. I and "Autoset Men".
LIMIT SWITCH SETTING MENU (reg FC)
See Fig. H and "L
S
S
imit
witch
etting
MONITORING
The torque parameter defines the maximum acceptable difference between the
instant torque and the expected instant torque , i.e. it indicates sensitivity to the
obstruction. The lesser the torque parameter, the greater the sensitivity to the
obstruction (Torque 1= maximum sensitivity).
14) ADJUSTING PROCEDURE
- Before switching on, check electrical connections.
- Set the following parameters: Automatic Closing Time, Opening and closing
delay times, speed and Slow-down Distance.
- Set all the logics.
- Carry out the autoset procedure.
After completing the autoset procedure, the Motor fast time and the Torque can
be manually adjusted.
WARNING! Any incorrect setting can cause injuries to persons and animals
or damage to things.
WARNING:check that the impact force value measured at
the points established by the EN 12445 standard is lower than that
specified in the EN 12453 standard.
To obtain a better result, it is advisable to carry out the autoset procedure and
the fast time setting with the motors at rest (i.e. not overheated by a considerable
number of consecutive manoeuvres).
Description
Set the numerical value of the automatic closing time from 0 to 120 seconds.
Set the opening delay time for motor 1 relative to motor 2, between 0,0 and 10,0
seconds. Adjust the time lag so that the minimum distance between the leaves,
when both are moving, is 50 cm.
Set the closing delay time for motor 2 relative to motor 1, between 0,0
and 60,0 seconds. Adjust the time lag so that the minimum distance between the
leaves, when both are moving, is 50 cm.
Set the numerical value of the motor 1 torque between 1% and 99%.
This parameter denotes sensitivity to the obstacle (couple=1 maximum sensitivity).
Set the numerical value of the motor 1 torque between 1% and 99%.
This parameter denotes sensitivity to the obstacle (couple=1 maximum sensitivity).
Sets the slow-down speed percentage between 15% and 50% of normal speed.
Sets the running speed that the motor must reach during opening, as a percenta-
ge of the maximum speed the actuator can reach. If this parameter is edited, the
autoset opening and closing cycle will need to be performed again.
Sets the running speed that the motor must reach during closing, as a percentage
of the maximum speed the actuator can reach. If this parameter is edited, the
autoset opening and closing cycle will need to be performed again.
Set the slow-down percentage between 5% and 59% with respect to the complete
manoeuvre.
Set the partial opening percentage for motor 2.
m
"
enu
HIDE SW - 15