Maintenance; Periodic Maintenance; Filter Replacement - PLYMOVENT DUAL GO Manual De Instalación Y De Uso

Ocultar thumbs Ver también para DUAL GO:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
• When the welding position changes, move the hood to the
correct position in relation to the weld.
WARNiNG
To keep the welding fume away from the breathing
zone of the welder, make sure that all fume is
extracted through the hood.
• Put the unit off approx. 20 seconds after you have finished
welding.
When the airflow is too low during use, the buzzer (ref. Fig.
5.1A) emits an acoustic alarm. Refer to chapter 7 to find the
possible cause and the solution.
ATTENTiON
If you do not replace the pre filter and/or the HEPA
filter cassette in time, the airflow (extraction
capacity) further drops.
6

MAiNTENANCE

6.1

Periodic maintenance

The product has been designed to function without problems
for a long time with a minimum of maintenance. In order to
guarantee this some simple, regular maintenance and cleaning
activities are required which are described in this chapter. If
you observe the necessary caution and carry out the
maintenance at regular intervals, any problems occurring will
be detected and corrected before they lead to a total
breakdown.
WARNiNG
Overdue maintenance can cause fire.
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore we
recommend to thoroughly inspect the complete product once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
Component
Action
Filter unit
Housing
Clean the outside with a
non-aggressive detergent
Clean the inside with an industrial
vacuum cleaner and remove dust
from the filter compartment
Check sealing material of the
door. Replace if necessary
Extraction
Check for encrusted particles.
fan
Clean if necessary
Mains cord
Check for damage. Repair or
replace if necessary
Extraction arm
Tubes
Clean the outside with a
non-aggressive detergent
Clean the inside thoroughly
Flexible
Check for cracks or damages.
hoses
Replace if necessary
Hood
Check the movement of the hood.
If necessary, adjust the friction;
refer to section 6.3
0000111692/150418/A DualGo
Component
Arm
movement
*) Before every use
6.2
The buzzer emits an acoustic signal when the airflow is too
low.
When the buzzer still continues, you must replace the filter
cassette(s).
As the pre filter is smaller and becomes more quickly saturated
than the HEPA filter, you can replace the pre filter cassette
several times before you finally need to replace the HEPA filter
cassette.
6.2.1
To replace the pre filter cassette, do the following.
Fig. 6.1
• De-energize the unit.
Frequency:
• Open the door (A).
every X months
• Remove the pre filter cassette (B).
• Dispose of the used filter cassette in accordance with state
X=6
X =12
• Put a new pre filter cassette in the unit. Make sure that the
X
• Close and lock the door.
X
X
X
X *)
X
X
X
Fig. 6.1 Replacement of the pre filter cassette
X
5. The arrow indicates the airflow direction
Action
Check horizontal, vertical and
diagonal arm movement. If
necessary, adjust the friction;
refer to section 6.3

Filter replacement

Make sure that:
- the shut-off damper is open
- the extraction arm is not fully folded
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you replace the filter
cassettes.
WARNiNG
Do not replace the filter cassettes while the fan is
running.
WARNiNG
Do not shake out or (vacuum) clean the used filter
cassettes to avoid the release of particles.
Pre filter cassette
or local regulations.
arrow on the frame points upwards
A
B
Frequency:
every X months
X=6
X =12
X
.
5
EN - 8
Tabla de contenido
loading

Este manual también es adecuado para:

Dual go plusMono goplus

Tabla de contenido