B
When the buzzer continues to beep after you have
replaced the pre filter cassette, it is time to replace
the HEPA filter cassette.
45°
6.2.2
HEPA filter cassette
To replace the HEPA filter cassette, do the following.
Fig. 6.2
• De-energize the unit.
• Open the front door (A).
• Remove the pre filter cassette.
• Loosen the wingnuts (C) and put the clips (B) in the
upright position. Make sure that the handle of the wingnut
is in a vertical position.
• Gently pull and remove the HEPA filter cassette (D).
• Dispose of the used HEPA filter cassette in accordance with
state or local regulations.
A
B
Fig. 6.2 Removal of the HEPA filter cassette
Fig. 6.2
• Put a new HEPA filter cassette in the unit. The side pins
exactly fit in the slits (A) inside the housing.
• Lock the HEPA filter cassette with the clips (B). Make sure
to push the clips in the slits (angle 45°).
• Tighten the wingnuts.
• Put the pre filter cassette back in the housing. Make sure
that the arrow on the frame points upwards
• Close and lock the door.
1
2
A
Fig. 6.3 Slits + clips (left + right)
6.3
Arm adjustment
If the extraction arm, or a part of it, does not stay in the
desired position, you must adjust the friction.
6.3.1
Hose tube arm (EconomyArm)
• Determine which joint needs more or less friction.
• Loosen the hose tube to get access to the hinges.
• Pull the arm in a horizontal position.
• Adjust the friction; refer to Fig. V on page 54 for the
adjustment points.
6. The arrow indicates the airflow direction. An incorrectly placed pre filter
cassette affects the filter lifetime.
0000111692/150418/A DualGo
B
C
C
.
6
B
45°
A
B
2
6.3.2
Metal tube arm (KUA)
• Determine which joint needs more or less friction.
• Loosen the hose at that position to get access to the hinge.
• Pull the arm in a horizontal position.
• Adjust the friction; refer to Fig. V on page 54 for the
adjustment points.
7
TROUBLEShOOTiNG
If the unit does not function (correctly), consult the checklist
below to see if you can remedy the error yourself. Should this
not be possible, contact your supplier.
WARNiNG
Obey the safety regulations that are written in
chapter 3 when you carry out the activities below.
Symptom
Problem
The fan does
The unit does
D
not start
not function
The green
The unit does
LED is on but
not function
the fan does
not run
The fan
Extraction
makes a
capacity
humming
insufficient or
sound, but
no extraction
does not run
at all
Poor
The unit does
extraction
not function
capacity
properly
The buzzer
Poor
emits an
extraction
acoustic
capacity
signal
D
B
C
B
45°
Possible
Solution
cause
No mains
Connect the mains
voltage
voltage
-
The mains cord
Repair or replace
is defective
the mains cord
Loose contacts
Repair the contacts
Motor defective
Repair or replace
the motor
Relay is
Replace the relay
defective
Thermal relay is
Replace the thermal
defective
relay
Motor defective
Repair or replace
the motor
Motor uses 2
Repair the phase
phases instead
connection
of 3
The shut-off
(Fully) open the
damper in the
shut-off damper
hood of the
extraction arm
is (partly)
closed
Inverted
Change the
direction of
direction of rotation
rotation of the
motor
Clogged filters
Repair the
& loose
connection of the
connection of
pressure tubes
pressure sensor
Clogged filters
Replace the
& defective
pressure sensor &
pressure sensor
the pre filter
cassette
Replace the HEPA
filter cassette as
well
The pre filter is
Replace the pre
clogged
filter cassette
The HEPA filter
Replace the HEPA
is clogged
filter cassette
A
B
EN - 9