DRAINING
8g
The SANICUBIC
Classic unit is fitted with 2 plugs (
®
Disconnect the unit from the power supply.
To drain the unit
1- Unclip the cover.
2- Remove one of the 2 plugs.
3- Insert a wet utility vacuum cleaner pipe to drain the unit. The
port diameter is 40 mm.
4- When the unit has been drained, put
the plug and then the cover back in place.
FIXING THE SANICUBIC UNIT TO THE FLOOR
8h
The SANICUBIC
Classic unit is equipped with fittings to hold it
®
on the floor and
prevent it from turning or moving.
1- Place the unit on the desired spot.
2- Draw the outline of the unit.
3- Position the brackets and fix them to the floor as shown on the
template diagram (
8h
1
4- Put the unit back in place.
5- Fix the unit in place with the screws.
ELECTRICAL CONNECTIONS
1- The electrical installation work must be carried out by a
8i
qualified electrician.
The electrical installation must comply with the standards in
force in the country concerned
2- The power supply must be of the class 1 type. The unit must be
connected via an earthed connection box. The electric power
circuit must be protected by a high-sensitivity 30 mA differential
circuit breaker set at 20 A. The connection must be used solely
to power the SANICUBIC
is damaged, it must be replaced by the manufacturer or its
after-sales service to avoid all danger.
9

ALARM OPERATION

1/ General alarms:
High level alarm:
If the water level in the unit is abnormally high: the buzzer is
triggered and the red LED comes on; the other motor starts up
3 seconds later (see the illustration showing the control
keyboard).
Temporary alarm:
If one of the 2 motors runs for more than 1 minute: the buzzer is
triggered and the red alarm LED comes on; the other motor starts
up 3 seconds later.
2/ Resetting the general alarms:
If the problem that has triggered one of the alarms referred to
above ceases, the buzzer stops, but the red alarm LED stays
on to memorize the fact that the system has met with a
problem.
The "Reset alarm" key on the keyboard is used to switch the
buzzer off in all cases, but it only switches the red LED off if
the problem that triggered the alarm has been dealt with. This
avoids the risk of having a system "abandoned" in fault status.
UNIT ALARM
motor 1
motor 2
"Alarm"
LED
LED
motor 1
motor 2
"Override"
"Override"
8g
).
Classic. If the power lead on the unit
®
"Mains"
LED
LED
"RESET"
Alarm
1 0

CONFORMITY WITH STANDARDS

).
• SANICUBIC
1
station for household waste containing faeces) and with the
European directives covering construction products, electrical
safety and electromagnetic compatibility
This unit must be installed and used in compliance with
European installation standard EN12056 and with local
requirements.
1 1
COMMISSIONING
1- Once the plumbing and electrical connections have been
made, check that the connections are watertight by
letting water flow successively through each inlet used.
Make sure that the unit is operating correctly by carrying
out at least two start cycles with water to test the system.
2 -
WARNING!
status (by pressing the pushbuttons
on the control box) until the pumps have been filled
with water. Operation without water damages the
maceration system.
USE
1 2
1- The SANICUBIC
household waste water. Any other use will invalidate the
guarantee. Do not dispose of sanitary towels, condoms,
hygiene articles, oils, solvents, acids, or any other poten-
tially corrosive or explosive liquids etc., via the unit.
2-
WARNING: In the event of a power failure, stop
draining any water from the equipment connected
to the SANICUBIC
3- Do not install or use the unit in a zone where there is a
risk of explosion.
1 3
MAINTENANCE
A visual check of the lift station must be made once a month
to make sure it is operating correctly, and the installation
must be inspected regularly (once a year) by a qualified
person. Meanwhile if encounter technical problems, please
ask our after-sales service for advice. If the power supply
cable of the unit is damaged, it must be replaced by the
manufacturer or its after-sales service to avoid all danger.
1 4
GUARANTEE
The SANICUBIC
(parts and labour) provided that it has been installed and
used in compliance with the present instructions.
complies with standard EN 12050-1 (lift
Classic
®
Do not operate the motors in override
unit is designed to drain off
Classic
®
Classic unit.
®
unit is guaranteed for two years