The plate data is displayed on an adhesive label placed on the outside of the casing,
which must remain intact and visible.
The main information it displays includes: manufacturer's address, product name -
model number, technical characteristics, production date and serial number. In the
event of a complaint, please indicate the serial number (SN) displayed on the label.
An explanation of the symbols used on the label to abbreviate the technical
characteristics is given in the table in the chapter on "TECHNICAL DATA".
6. Construction and standards
INTENDED USE. The RACK MAX 450 actuator has been designed and
manufactured to open and close top hung windows opening outwards, bottom
hung windows, dormer windows, light domes and skylights. Specific use is for
ventilation and airing of areas; any other use is strongly discouraged, with the
supplier of the entire system in any case retaining sole liability.
The actuator is manufactured in accordance with the Directives and following
Regulations listed in the attached Declaration of Incorporation and Conformity UE.
Electrical connections must conform to regulations in force for the design and
set up of electrical equipment.
To ensure efficient separation from the grid, an approved type of bipolar "dead-man"
switch should be used. An omnipolar general power switch with minimum distance
of 3 mm between contacts should be installed upstream of the control line.
Application is performed using the brackets provided and any other type of
assembly should be checked with the manufacturer, who will not accept any
responsibility for incorrect or malfunctioning assembly.
The actuator comes packaged in a cardboard container. Each package contains:
• Nr. 1
110-230V~ 50/60Hz electrical actuator
• Nr. 1
Standard support bracket with respective grip and fixing screws.
(Grip and fixing screws are inside small part packaging).
• Nr. 1
Bracket for fixing to the frame.
• Nr. 1
Small part packaging.
• Nr. 1
Instruction manual.
7.
Electrical power supply
RACK MAX 450 is commercially available in one single version:
▪ RACK MAX 450 230V: runs on grid tension of 110-230V~ 50/60Hz, with a three
wire cable (L
IGHT
closed).
7.1
Section choice of supply cables
Tension falls due to current passage in conductors is a basic aspect for safety and
good appliance function. It is therefore extremely important that the conductor section in
B
, common neutral; B
LUE
, phase open; B
LACK
28
, phase
ROWN