AquaPRO 63043 Manual Del Propietário página 17

Ocultar thumbs Ver también para 63043:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Problem
Possible Cause
Pump starts and
1. Incorrect tank pre-charged
stops too often
2. Ruptured diaphragm/bladder
(pre-charged tank)/or has no air cushion
3. Pipes leak
4. Foot valve leaks
5. Improperly adjusted pressure switch
6. Air charge too low in pre-charged tank
Pump does not
1. Water level is lower than estimated
shut off
2. Pipes leak
3. Improper setting of pressure switch
Corrective Action
1. Add or release air as needed
2. Replace tank/refill air
3. Repair pipes connection or replace pipes
4. Repair or replace the foot valve
5. Closely look at the pressure gauge to see
the pump On/Off points are around 30 psi/50
psi, if not, adjust or replace the pressure
switch
6. DISCONNECT POWER and open faucets
until all pressure is relieved. Using tire
pressure gauge, check air pressure in tank
at valve stem located on the tank. If less
than pressure switch cut-in setting (30 psi),
pump air into tank from outside source until
air pressure is 2 psi less than cut-in setting
of switch. Check air valve for leaks (use
soapy solution) and replace core if
necessary.
1. Use deep well installation
2.Locate and repair leak or reconnect
3. Reset or replace pressure switch
17
Tabla de contenido
loading

Tabla de contenido